Optic Nerve Sheath Diameter Correlation with Elevated Intracranial Pressure Determined via Ultrasound
نویسندگان
چکیده
منابع مشابه
sonographic optic nerve sheath diameter as a screening tool for detection of elevated intracranial pressure
introduction: timely diagnosis and treatment of post traumatic, elevated intracranial pressure (eicp), could reduce morbidity and mortality, as well as improve patients’ outcome. this study is trying to evaluate the diagnostic accuracy of sonographic optic nerve sheath diameter (onsd) in detection of eicp. methods: sonographic onsd of patients with head trauma or cerebrovascular accident suspic...
متن کاملCorrelation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure
Background: Measurements of the optic nerve sheath diameter (ONSD) using bedside ultrasound (US) have been shown to correlate with clinical and radiologic signs and symptoms of increased intracranial pressure (ICP). Objectives: Previous literature has identified 5 mm as the ONSD measurement above which patients exhibit either clinical or radiologic signs of elevated ICP. The goals of this study...
متن کاملCorrelation of optic nerve sheath diameter with direct measurement of intracranial pressure.
BACKGROUND Measurements of the optic nerve sheath diameter (ONSD) using bedside ultrasound (US) have been shown to correlate with clinical and radiologic signs and symptoms of increased intracranial pressure (ICP). OBJECTIVES Previous literature has identified 5 mm as the ONSD measurement above which patients exhibit either clinical or radiologic signs of elevated ICP. The goals of this study...
متن کاملOptic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure
A previously fit and healthy 26-year-old lady with no significant medical history presented with a two-month history of headaches. The headaches were prolonged, generalised, and unusually severe for the patient. Examination revealed papilloedema. The patient's optic nerve sheath diameter was measured 3 mm posterior to the globe and found to be 7.5 mm. The patient subsequently had computed tomog...
متن کاملSonographic Optic Nerve Sheath Diameter as a Screening Tool for Detection of Elevated Intracranial Pressure
INTRODUCTION Timely diagnosis and treatment of post-traumatic elevated intracranial pressure (EICP) could be reduced morbidity and mortality, and improved patients' outcome. This study is trying to evaluate the diagnostic accuracy of sonographic optic nerve sheath diameter (ONSD) in detection of EICP. METHODS Sonographic ONSD of patients with head trauma or cerebrovascular accident suspicious...