Optic axis mapping with catheter-based polarization-sensitive optical coherence tomography
نویسندگان
چکیده
منابع مشابه
Optic axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography.
We present a generalized analysis of fiber-based polarization-sensitive optical coherence tomography with an emphasis on determination of sample optic axis orientation. The polarization properties of a fiber-based system can cause an overall rotation in a Poincaré sphere representation such that the plane of possible measured sample optic axes for linear birefringence and diattenuation no longe...
متن کاملMapping local optical axis in birefringent samples using polarization-sensitive optical coherence tomography.
An algorithm was developed to obtain depth-resolved local optical axis in birefringent samples by using conventional polarization-sensitive optical coherence tomography (PSOCT) that uses a single circularly polarized incident light. The round-trip sample Jones matrices were first constructed from the cumulative PSOCT results. An iterative method was then applied to construct the depth-resolved ...
متن کاملPolarization-sensitive quantum optical coherence tomography: Experiment
a Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA b Quantum Photonics Laboratory, Department of Electrical & Computer Engineering, Boston University, Boston, MA 02215, USA c Quantum Photonics Laboratory, College of Optics and Photonics (CREOL), University of Central Florida, Orlando, FL 32816, USA d Department of Electrical Engineering, Columbia University, New Yo...
متن کاملPolarization-sensitive quantum-optical coherence tomography
Mark C. Booth, Giovanni Di Giuseppe,* Bahaa E. A. Saleh, Alexander V. Sergienko, and Malvin C. Teich Quantum Imaging Laboratory, Department of Biomedical Engineering, Boston University, 8 Saint Mary’s Street, Boston, Massachusetts 02215, USA Quantum Imaging Laboratory, Department of Electrical & Computer Engineering, Boston University, 8 Saint Mary’s Street, Boston, Massachusetts 02215, USA Qua...
متن کاملConical scan polarization-sensitive optical coherence tomography.
We report on a new articular cartilage imaging technique with potential for clinical arthroscopic use, by supplementing the variable-incidence-angle polarization-sensitive optical coherence tomography method previously developed by us with a conical beam scan protocol. The technique is validated on bovine tendon by comparing experimental data with simulated data generated using the extended Jon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optica
سال: 2018
ISSN: 2334-2536
DOI: 10.1364/optica.5.001329