Operation of the DC Current Transformer intensity monitors at FNAL during Run II
نویسندگان
چکیده
منابع مشابه
Secondary Beam Monitors for the NuMI Facility at FNAL
The Neutrinos at the Main Injector (NuMI) facility is a conventional neutrino beam which produces muon neutrinos by focusing a beam of mesons into a long evacuated decay volume. We have built four arrays of ionization chambers to monitor the position and intensity of the hadron and muon beams associated with neutrino production at locations downstream of the decay volume. This article describes...
متن کاملBeam Current Monitors at the UNILAC
One of the most basic linac operation tools is a beam current transformer. Using outstanding materials, the latest low-noise amplifiers, and some good ideas, a universal current monitoring system has been developed and installed at the UNILAC at GSI. With a dynamic range of 112 dB, covering the low-current range down to 100 nA peak to peak at S/N=1, as well as 25 mA pulses, provided for high-cu...
متن کاملCollider Physics at FNAL
After a three year hiatus, the Fer~ab Tevatron CoUder is back in operation defiverirrgfi coUsions at V = 1.8 TeV. The experimented situation is considerably Merent this run with an upgraded CDF detector jotied by the new DO detector. kprovements to the accelerator are expected to de~ver 100 pb1 from a run extending into 1993. Mer a description of the detectors and accelerator schedrde, recent p...
متن کاملthe effect of e-64 on the developmental competence of sheep cocs during in vitro maturation
in the present study, the effect of e-64 at different concentrations (0.5, 1, 5 and 10 µm) added to (1) the ivm medium on oocyte nuclear maturation and developmental competence of ovine oocytes, and (2) to the ivc medium on embryonic development of ovine embryos were investigated.
A Zero-Voltage and Zero-Current Switching Full Bridge DC–DC Converter With Transformer Isolation
A new primary-side-assisted zero-voltage and zerocurrent switching full bridge dc–dc converter with transformer isolation is proposed. The proposed dc–dc converter uses only one auxiliary transformer and two diodes to obtain ZCS for the leading leg. It has a simple and robust structure, and load current control capability even in short circuit conditions. Possibility of magnetic saturation due ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2012
ISSN: 1748-0221
DOI: 10.1088/1748-0221/7/01/t01002