OPERATION OF BASED IMPEDANCE PROTECTION NUMERICAL RELAY WITH STATCOM FACTS DEVICES
نویسندگان
چکیده
منابع مشابه
Impedance-Based Out-of-Step Protection of Generator in the Presence of STATCOM
This paper presents a novel impedance-based approach for out-of-step (OOS) protection of a synchronous generator. The most popular and commonly used approaches for detecting OOS conditions are based on the measurement of positive sequence impedance at relay location. However, FACTS devices change the measured impedance value and thus disrupt the performance of impedance-based relay function. In...
متن کاملEffects of CT and VT Connection Point on Distance Protection of Transmission Lines with FACTS Devices
This paper presents the effects of instrument transformers connection points on the measured impedance by distance relays in the presence of Flexible Alternating Current Transmission System (FACTS) devices with series connected branch. Distance relay tripping characteristic itself depends on the power system structural conditions, pre-fault operational conditions, and especially the ground ...
متن کاملInvestigation of STATCOM effects on synchronous generator impedance based LOF relay with considering a realistic model for the excitation system of the generator
This paper studies the effects of static synchronous compensator (STATCOM) on synchronous generator conventional loss of field (LOF) protection. To accomplish a comprehensive study, a typical and realistic excitation system is considered for the generator by using the phase-domain generator model available in the real-time-digital-simulator. Using such a system, LOF phenomenon is realistically ...
متن کاملReliability of microprocessor-based relay protection devices - myths and reality
Malfunction of relay protection is one of the main causes of the serious failures that periodically occur in power systems all over the world. According to the North American Electric Reliability Council [1] in 74 % cases the reason for heavy failures in power systems was the incorrect actions of relay protection in trying to avoid the failure. Thus the reliability of a power system depends on ...
متن کاملReliability of Microprocessor-Based Relay Protection Devices: Myths and Reality
The article examines four basic theses about the ostensibly extremely high reliability of microprocessor-based relay protection (MP) touted by supporters of MP. Through detailed analysis based on many references it is shown that the basis of these theses are widespread myths, and actually MP reliability is lower than the reliability of electromechanical and electronic protective relays on discr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JES. Journal of Engineering Sciences
سال: 2009
ISSN: 2356-8550
DOI: 10.21608/jesaun.2009.127768