OPEN SWITCH FAULT DIAGNOSIS IN THREE PHASE INVERTER USING DIAGNOSTIC VARIABLE METHOD
نویسندگان
چکیده
منابع مشابه
Fault Diagnosis and Fault-Tolerant SVPWM Technique of Six-phase Converter under Open-Switch Fault
In this paper, a new open-switch fault diagnosis method is proposed for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The open-switch faults are detected without any additional equipment and complicated calculations, since the proposed fault detection method is integrated with the controller required ...
متن کاملWavelet Entropy-Based Traction Inverter Open Switch Fault Diagnosis in High-Speed Railways
Keting Hu 1,2, Zhigang Liu 1,2,* and Shuangshuang Lin 1,2 1 Key Laboratory of Magnetic Suspension Technology and Maglev Vehicle, Ministry of Education, Southwest Jiaotong University, Chengdu 610031, China; [email protected] (K.H.); [email protected] (S.L.) 2 School of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, China * Correspondence: [email protected]....
متن کاملInverter Switch Fault Diagnosis System for BLDC Motor Drives
Safe operation of electric motor drives is of prime research interest in various industrial applications. This paper presents a new fault diagnosis system for open circuit switch faults in three phases Voltage Source Inverter (VSI) drive of the permanent magnet Brushless DC (BLDC) motors. The proposed fault diagnosis system is capable of detecting as well as identifying the faulty switch in the...
متن کاملFault Tolerant Control of Four Switch Three Phase Inverter Fed Induction Motor Drive System
In this paper a new switching technique for Direct Torque Control (DTC) fault tolerant induction motor drive is presented, if one inverter leg is completely lost due to such abnormal condition, this system modifies the switching table of DTC system using the available stator voltage vectors in two phase mode with Four Switch Three Phase Inverter (FSTPI) topology to track the stator flux referen...
متن کاملHarmonics Analysis of Four Switch Three Phase Inverter
In the viewpoint of reliability implication and cost effectiveness of three phase inverter, there should be less device count in inverter topology and fewer losses in the semiconductor switches. The earlier reported less device count topology by many research groups are facing the problem of Total Harmonic Distortion (THD). The imperfect design value of DC link capacitor is the main reason of H...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Research in Engineering and Technology
سال: 2013
ISSN: 2321-7308,2319-1163