Open-Switch Fault Detection Based on Open-Winding Five-Phase Fault-Tolerant Permanent-Magnet Motor Drives
نویسندگان
چکیده
The difficulty of open-switch fault detection in an open-winding inverter is that the at diagonally opposite position within H-bridge power cell has same characteristics. To solve this problem, paper proposes method based on (OW) five-phase fault-tolerant permanent-magnet (FPFTPM) motor drives. includes three steps: first, drives detected by monitoring component third harmonic residual stationary reference frame; second, least squares iterative forgetting factor used to identify relationship between components, which determines faulty phase and current type; third, online injection test proposed accurately cell. Based above steps, could be identified. novelty lies possibility any switches one achieved does not require hardware changes. experimental results demonstrate effectiveness method.
منابع مشابه
Fault Diagnosis and Fault-Tolerant SVPWM Technique of Six-phase Converter under Open-Switch Fault
In this paper, a new open-switch fault diagnosis method is proposed for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The open-switch faults are detected without any additional equipment and complicated calculations, since the proposed fault detection method is integrated with the controller required ...
متن کاملOpen-Phase Fault Tolerance Techniques of Five-Phase Dual-Rotor Permanent Magnet Synchronous Motor
Abstract: Multi-phase motors are gaining more attention due to the advantages of good fault tolerance capability and high power density, etc. By applying dual-rotor technology to multi-phase machines, a five-phase dual-rotor permanent magnet synchronous motor (DRPMSM) is researched in this paper to further promote their torque density and fault tolerance capability. It has two rotors and two se...
متن کاملSingle Open-phase Fault Detection with Fault-Tolerant Control of an Inverter-fed Permanent Magnet Synchronous Machine
In this paper first a current predictive method for single open-phase fault detection in a three phase drive with a permanent magnet synchronous machine is presented. The proposed method is based on a predictive stator current calculation. For each sampling interval the difference between the actual stator current and its predicted value in a previous sampling interval is calculated. To identif...
متن کاملOpen-Phase Fault Operation on Multiphase Induction Motor Drives
Multiphase machines have been recognized in the last few years like an attractive alterna‐ tive to conventional three-phase ones. This is due to their usefulness in a niche of applica‐ tions where the reduction in the total power per phase and, mainly, the high overall system reliability and the ability of using the multiphase machine in faulty conditions are required. Electric vehicle and rail...
متن کاملFault-Tolerant Voltage Source Inverter for Permanent Magnet Synchronous Motor
A two level fault tolerant voltage sourse inverter(VSI) for permanent magnetic drives is designed and tested. Generally a two level inverter consists of three legs. In this case an extra (redundant ) leg is added that replaces the fault leg. Extra leg is added by using by back to back connected thyristor this inverter works on both open circuit and short circuit fault. The main advantage is pos...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Machines
سال: 2022
ISSN: ['2075-1702']
DOI: https://doi.org/10.3390/machines10100829