Open-path ozone detection by quantum-cascade laser
نویسندگان
چکیده
منابع مشابه
Open-path, quantum cascade-laser-based sensor for high-resolution atmospheric ammonia measurements
We demonstrate a compact, open-path, quantum cascade-laser-based atmospheric ammonia sensor operating at 9.06 μm for high-sensitivity, high temporal resolution, ground-based measurements. Atmospheric ammonia (NH3) is a gas-phase precursor to fine particulate matter, with implications for air quality and climate change. Currently, NH3 sensing challenges have led to a lack of widespread in situ m...
متن کاملOzone detection by differential absorption spectroscopy at ambient pressure with a 9.6 μm pulsed quantum-cascade laser
We report direct absorption spectroscopic detection of ozone at ambient pressure with a pulsed, DFB quantumcascade laser (QCL) tuned within 1044–1050 cm−1 by temperature scanning. Wavelength calibration curves were derived from FTIR and CO2 spectra and interpreted with respect to the heat transfer from the heterostructure to the sink. The laser linewidth (∼ 0.13 cm−1 FWHM) was found to decrease...
متن کاملQuantum dot cascade laser
UNLABELLED We demonstrated an unambiguous quantum dot cascade laser based on InGaAs/GaAs/InAs/InAlAs heterostructure by making use of self-assembled quantum dots in the Stranski-Krastanow growth mode and two-step strain compensation active region design. The prototype generates stimulated emission at λ ~ 6.15 μm and a broad electroluminescence band with full width at half maximum over 3 μm. The...
متن کاملQuantum cascade laser technology
In the mid-infrared spectral region, where continuous wave room temperature operation of the QCL devices was achieved in the previous phase of the program, the main goal will be to further broaden the frequency range over which these high performances are achieved. Another important topic is the fabrication of devices with a very large frequency tuning capability, which will enable the spectros...
متن کاملQuantum cascade laser-based sensor system for nitric oxide detection
Sensitive detection of nitric oxide (NO) at ppbv concentration levels has an important impact in diverse fields of applications including environmental monitoring, industrial process control and medical diagnostics. For example, NO can be used as a biomarker of asthma and inflammatory lung diseases such as chronic obstructive pulmonary disease. Trace gas sensor systems capable of high sensitivi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Physics B
سال: 2005
ISSN: 0946-2171,1432-0649
DOI: 10.1007/s00340-005-2010-3