Online thevenin’s equivalent using local PMU measurements

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Online Inertia Constant and Thévenin Equivalent Estimation Using PMU Data

In this paper a new algorithm based on phasor measurements for estimating the Thévenin Equivalent (TE) and system inertia constant is proposed. The method estimates the network TE seen from a generator terminal and equivalent system inertia constant by means of phasor data that is available at Phasor Data Concentrator (PDC) center. It is shown that the parameters of the TE could be estimated at...

متن کامل

online inertia constant and thévenin equivalent estimation using pmu data

in this paper a new algorithm based on phasor measurements for estimating the thévenin equivalent (te) and system inertia constant is proposed. the method estimates the network te seen from a generator terminal and equivalent system inertia constant by means of phasor data that is available at phasor data concentrator (pdc) center. it is shown that the parameters of the te could be estimated at...

متن کامل

Transmission line parameter identification using PMU measurements

Accurate knowledge of transmission line (TL) impedance parameters helps to improve accuracy in relay settings and power flow modeling. To improve TL parameter estimates, various algorithms have been proposed in the past to identify TL parameters based on measurements from Phasor Measurement Units (PMU’s). These methods are based on the positive sequence TL models and can generate accurate posit...

متن کامل

Automated Anomaly Detection in Distribution Grids Using $\mu$PMU Measurements

The impact of Phasor Measurement Units (PMUs) for providing situational awareness to transmission system operators has been widely documented. Micro-PMUs (μPMUs) are an emerging sensing technology that can provide similar benefits to Distribution System Operators (DSOs), enabling a level of visibility into the distribution grid that was previously unattainable. In order to support the deploymen...

متن کامل

Observability-Enhanced PMU Placement Considering Conventional Measurements and Contingencies

Phasor Measurement Units (PMUs) are in growing attention in recent power systems because of their paramount abilities in state estimation. PMUs are placed in existing power systems where there are already installed conventional measurements, which can be helpful if they are considered in PMU optimal placement. In this paper, a method is proposed for optimal placement of PMUs incorporating conve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Renewable Energy and Power Quality Journal

سال: 2011

ISSN: 2172-038X,2172-038X

DOI: 10.24084/repqj09.604