One-way valve malfunction in a circle system
نویسندگان
چکیده
منابع مشابه
One-way valve malfunction in an extracorporeal membrane oxygenation priming circuit.
Developing technologies have changed both the components and the management style when extracorporeal membrane oxygenation (ECMO) is used to support critically ill cardiac and respiratory patients. The Cardiohelp system is a small, portable extracorporeal system just recently available within the United States. Manufacturing standards and quality processes have made mechanical failure and malfu...
متن کاملA bi-polymer micro one-way valve
We have developed an in-plane bi-polymer check-valve for controlling microfluidic flow and preventing contamination between solutions by tilizing the elastic force of a swollen hydrogel. The valve was created using microfluidic tectonics, a fabrication procedure that allows construction f microscale components and autonomous systems using liquid-phase photopolymerization and in situ fabrication...
متن کاملUse of a one-way flutter valve drainage system in the postoperative period following lung resection.
OBJECTIVE To evaluate pleural drainage using a one-way flutter valve following elective lung resection. METHODS This was a prospective study, with descriptive analysis, of 39 lung resections performed using a one-way flutter valve to achieve pleural drainage during the postoperative period. Patients less than 12 years of age were excluded, as were those submitted to pneumonectomy or emergency...
متن کاملA Mems Micropump System with One-way Valve for Chronic Drug Delivery
Implantable micropump systems capable of user-controlled and site-specific chronic drug delivery in small animals are a critical unmet need in drug discovery and development. Our electrochemical bellows actuator provides current-controlled flow rate and is integrated to form a fully implantable system with a refillable reservoir and one-way valve that prevents mixing of biological fluids with t...
متن کاملMalfunction of an adjustable pressure limit valve.
EDITOR: We report the malfunction of an adjustable pressure limit (APL) valve on a KION (Siemens, SiemensElema AB, Solna, Stockholm, Sweden) anaesthesia workstation which occurred twice. The first time, the malfunction was detected during the pre-use manual check, but not by the automatic self-check. The second time, the malfunction occurred intermittently during ventilation of a patient but it...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 1995
ISSN: 0003-2409,1365-2044
DOI: 10.1111/j.1365-2044.1995.tb05886.x