One-step non-competitive fluorescence polarization immunoassay based on a Fab fragment for C-reactive protein quantification
نویسندگان
چکیده
A non-competitive fluorescence polarization immunoassay (FPIA) using a Fab fragment was developed for large molecule quantification. Most conventional FPIAs are homogeneous and competitive immunoassays. With FPIAs, it has been difficult to obtain sufficient detection sensitivity when targeting molecules like proteins. To overcome this fundamental drawback, we report FPIA fluorescence-labeled fragment. C-reactive protein (CRP) used as model substance validation of the Fab-based FPIA. Quantitative analysis CRP in phosphate buffered saline (PBS) successfully achieved limit (LOD) PBS 207 ng/mL. Moreover, far-red emitting fluorescent dye (HiLyte Fluor™647) labeling fragment, measured human serum without pretreatment sample 10 min around cut-off value (10 μg/mL). The LOD 1.58 μg/mL. In our proposed method, reaction completed simple one-step mixing with only one type reagent, no washing operation required. Therefore, rapid quantification greatly simplified procedure.
منابع مشابه
Development of one-step fluorescence polarization immunoassay for progesterone.
A one-step fluorescence polarization immunoassay (FPIA) was developed to measure progesterone level using an immunocomplex single reagent (SR), a preequilibrated mixture of antibody and tracer. Several fluorescence-labeled progesterone tracers were synthesized using the combination of two progesterone derivatives, 11alpha-hemisuccinyloxyprogesterone (P-11HS) and progesterone-3-(O-carboxymethyl)...
متن کاملSurface plasmon resonance-based immunoassay for human C-reactive protein.
A rapid and highly-sensitive surface plasmon resonance (SPR)-based immunoassay (IA) has been developed and validated for detecting human C-reactive protein (CRP), a specific biomarker for inflammatory and metabolic disorders, and infections. The 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC)-activated protein A/G (Pr A/G) was diluted in 1% (v/v) 3-aminopropyltriethoxysilane ...
متن کاملCompetitive quenching fluorescence immunoassay for chlorophenols based on laser-induced fluorescence detection in microdroplets.
An improved biomonitoring system for the analysis of 2,4,6-trichlorophenol (TCP) in urine samples has been developed. The principle of the biosensor device is the detection of laser-induced fluorescence (LIF) in single microdroplets by a homogeneous quenching fluorescence immunoassay (QFIA). The competitive immunoassay occurs in microdroplets (d = 58,4 microm) produced by a piezoelectric genera...
متن کاملTime-Resolved Fluorescence Immunoassay for C-Reactive Protein Using Colloidal Semiconducting Nanoparticles
Besides the typical short-lived fluorescence with decay times in the nanosecond range, colloidal II/VI semiconductor nanoparticles dispersed in buffer also possess a long-lived fluorescence component with decay times in the microsecond range. Here, the signal intensity of the long-lived luminescence at microsecond range is shown to increase 1,000-fold for CdTe nanoparticles in PBS buffer. This ...
متن کاملFluorescence Polarization Immunoassay of Mycotoxins: A Review
Immunoassays are routinely used in the screening of commodities and foods for fungal toxins (mycotoxins). Demands to increase speed and lower costs have lead to continued improvements in such assays. Because many reported mycotoxins are low molecular weight (below 1 kDa), immunoassays for their detection have generally been constructed in competitive heterogeneous formats. An exception is fluor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors and Actuators B-chemical
سال: 2021
ISSN: ['0925-4005', '1873-3077']
DOI: https://doi.org/10.1016/j.snb.2020.128982