On the new metrics for IMRT QA verification

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A survey on planar IMRT QA analysis

Quality assurance (QA) systems for intensity-modulated radiation therapy (IMRT) have become standard tools in modern clinical medical physics departments. However, because formalized industry standards or recommendations from professional societies have yet to be defined, methods of IMRT QA analysis vary from institution to institution. Understanding where matters stand today is an important st...

متن کامل

Image processing for IMRT QA dosimetry

We have automated the determination of the placement location of the dosimetry ion chamber within intensity-modulated radiotherapy (IMRT) fields, as part of streamlining the entire IMRT quality assurance process. This paper describes the mathematical image-processing techniques to arrive at the appropriate measurement locations within the planar dose maps of the IMRT fields. A specific spot wit...

متن کامل

Breaking bad IMRT QA practice

Agreement between planned and delivered dose distributions for patient-specific quality assurance in routine clinical practice is predominantly assessed utilizing the gamma index method. Several reports, however, fundamentally question current IMRT QA practice due to poor sensitivity and specificity of the standard gamma index implementation. An alternative is to employ dose volume histogram (D...

متن کامل

Guidelines for the Verification of Imrt Guidelines for the Verification of Imrt

V ACKNOWLEDGEMENTS When writing a booklet about a topic that is under rapid development such as the clinical introduction of an advanced treatment technique like IMRT, there is a chance that at the time of publication many solutions might already be obsolete or replaced by other approaches. We therefore greatly appreciate very much that we got the latest information from the participating centr...

متن کامل

Reproducibility in patient‐specific IMRT QA

The purpose of this study was to determine the reproducibility of patient-specific, intensity-modulated radiation therapy (IMRT) quality assurance (QA) results in a clinical setting. Six clinical patient plans were delivered to a variety of devices and analyses, including 1) radiographic film; 2) ion chamber; 3) 2D diode array delivered and analyzed in three different configurations (AP deliver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medical Physics

سال: 2016

ISSN: 0094-2405

DOI: 10.1118/1.4964796