منابع مشابه
Elastic Initial and Post-local Buckling of Profiled through Girders
An experiment investigating the elastic local buckling response of trough girders composed of thin profiled steel sheeting has been undertaken Beam tests were performed to promote initial local buckling in a region of constant moment in the elastic range of structural response. The results of the experiments were compared with an elastic complex semi-analytical finite strip method of analysis, ...
متن کاملOn the magnetorotational instability and elastic buckling.
This paper demonstrates an equivalence between rotating magnetized shear flows and a stressed elastic beam. This results from finding the same form of dynamical equations after an asymptotic reduction of the axis-symmetric magnetorotational instability (MRI) under the assumption of almost-critical driving. The analysis considers the MRI dynamics in a non-dissipative near-equilibrium regime. Bot...
متن کاملBuckling modes of elastic thin films on elastic substrates
Two buckling modes have been observed in thin films: buckle delamination and wrinkling. This letter identifies the conditions for selecting the favored buckling modes for elastic films on elastic substrates. Transition from one buckling mode to another is predicted as the stiffness ratio between the substrate and the film or is predicted for variation of the stiffness ratio between the substrat...
متن کاملbuckling of viscoelastic composite plates using the finite strip method
در سال های اخیر، تقاضای استفاده از تئوری خطی ویسکوالاستیسیته بیشتر شده است. با افزایش استفاده از کامپوزیت های پیشرفته در صنایع هوایی و همچنین استفاده روزافزون از مواد پلیمری، اهمیت روش های دقیق طراحی و تحلیل چنین ساختارهایی بیشتر شده است. این مواد جدید از خودشان رفتارهای مکانیکی ارائه می دهند که با تئوری های الاستیسیته و ویسکوزیته، نمی توان آن ها را توصیف کرد. این مواد، خواص ویسکوالاستیک دارند....
Excessive Long-Time Deflections of Prestressed Box Girders
The segmental prestressed concrete box girder of Koror-Babeldaob (KB) Bridge in Palau, which had the record span of 241 m (791 ft.), presents a striking paradigm of serviceability loss due to excessive multi-decade deflections. The data required for analysis have recently been released and are here exploited to show how the analysis and design could be improved. Erected segmentally in 1977, thi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Japan Society of Civil Engineers
سال: 1965
ISSN: 1884-4944,0047-1798
DOI: 10.2208/jscej1949.1965.120_8