ON THE DYNAMIC BEHAVIOR OF BRACED STEEL FRAMES
نویسندگان
چکیده
منابع مشابه
effect of easy-going steel concept on the behavior of diagonal eccentrically braced frames
from the time that civil engineers have used steel in building structures, they tried to increase its strength so as to produce more economic and lighter structures by using more elegant sections. increase of steel strength is not always useful for all members of a steel structure. in some members under certain conditions, it is needed to reduce the strength as much as possible to improve the b...
متن کاملTubular Brace Member Connections in Braced Steel Frames
cast connections. ABSTRACT: Diagonal bracings are extremely popular elements for lateral load resistance in steel-framed buildings. In turn, the most common shape used for bracing members is the hollow structural section. While the design of such members is straight-forward, the design of gusset-plate connections at the member ends is controversial. This paper reviews the current ‘state-of-the-...
متن کاملSEISMIC RELIABILITY ASSESSMENT OF OPTIMALLY DESIGNED STEEL CONCENTIRCALLY BRACED FRAMES
The main aim of this study, is to evaluate the seismic reliability of steel concentrically braced frame (SCBF) structures optimally designed in the context of performance-based design. The Monte Carlo simulation (MCS) method and neural network (NN) techniques were utilized to conduct the reliability analysis of the optimally designed SCBFs. Multi-layer perceptron (MLP) trained by back propagati...
متن کاملNumerical study on the behavior of link-to-column connections in eccentrically braced frames
Geometry of eccentrically braced frames (EBFs) in some cases causes the connection of link beam to the column. The details of such conditions should be studied carefully due to the full plastic rotation in the link beam. In this research, the behavior of link-to-column connection is modeled and the failure modes are considered. Based on the previous researches shear link can exhibit better beha...
متن کاملSeismic Behavior of Asymmetric Two-Story X-braced Frames
Concentrically braced frames (CBFs) are one of the efficient lateral load resisting systems in high seismicity regions. One of the common problems with the use of concentrically braced frames is limitation in the architectural application and position of the openings. Two-story X braced frames have more advantages than other configurations of concentrically braced frames, since in many cases th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Architectural Institute of Japan
سال: 1978
ISSN: 0387-1185,2433-0027
DOI: 10.3130/aijsaxx.270.0_43