On-line Radiocarbon Measurements of Small Samples Using Elemental Analyzer and MICADAS Gas Ion Source
نویسندگان
چکیده
منابع مشابه
hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
On-Line Sulfur-Isotope Determination Using an Elemental Analyzer Coupled to a Mass Spectrometer
An on-line method for S-isotope analysis is described. Samples are combusted in an elemental analyzer. SO2 is separated from other combustion gases by gas chromatography, and the gases enter the ion source of the mass spectrometer through a split interface. Integrated peak areas for %O2+ and %OZ+ are compared to the response for a standard gas sample to determine the 6% value. 6% values of samp...
متن کاملon the relationship between using discourse markers and the quality of expository and argumentative academic writing of iranian english majors
the aim of the present study was to investigate the frequency and the type of discourse markers used in the argumentative and expository writings of iranian efl learners and the differences between these text features in the two essay genres. the study also aimed at examining the influence of the use of discourse markers on the participants’ writing quality. to this end the discourse markers us...
15 صفحه اولCalculation of plasma chloride levels using blood gas measurements
Objective: Chloride is the major plasma anion. There are several methods available for the determination of serum chloride levels. Unfortunately these methods are sometimes not available in the urgent setting where values are needed. Here we describe...
متن کاملCalibration of a Quadrupole Gas Analyzer Using a Reference Gas*
A quadrupole gas analyzer system was calibrated for the gases H2, He, N2, 02, A, and Xe. The procedure involved first calibrating the system for argon, as the reference gas. This was done using conventional techniques. A mixture of the above gases was then introduced into the system to be calibrated. The system configuration was such that the ratio of the partial pressures of each of the test g...