On-line Partial Discharge Assessment and Monitoring of MV to EHV Cables

To effectively manage their electricity networks, owners and operators around the world have a very real need to understand the condition of their often ageing Transmission and Distribution assets. Of all the major asset classes, underground cables often have the least available condition data but at the same time have a significant impact on network performance. One of the predominant causes o...

متن کامل

DSP Based On-line Partial Discharge Monitoring System for High Voltage Power Cable

In high voltage power cable system, partial discharge (PD) is a common phenomenon which reflects the degradation of insulation. When partial discharge happens inside the cable, leakage current will flow through the grounded conductor. To couple the partial discharge current, one feasible and effective method is placing a clamp-on high frequency current transformer around the grounded strap. In ...

متن کامل

Partial Discharge in High Voltage Insulating Materials

High voltage transmission has been chosen in electric power system due to its capability to transfer a large amount of electric power. Several key equipments such as generator, transformer, GIS, cable and insulator play important role in determining the reliability of the power system. The high voltage equipments in general contain gas, liquid or solid insulation. Defects and a particular condi...

متن کامل

On-line Partial Discharge Monitoring System and Data Processing Using WTST-NST Filter for High Voltage Power Cable

Defects inside insulation of HV XLPE cable accessories can lead to partial discharge (PD) activity. When PD activity happens, leakage current may flow through the grounded line. To acquire the PD current signal, one practicable and effective method is placing a high frequency current transformer (HFCT) winding the grounded line. In order to measure the insulation degradation, a partial discharg...

متن کامل

Partial Discharges in Low-Voltage Cables

Testing of high voltage apparatus for partial discharges has long been recognized as an important part of quality control for these devices. Recently, interest has been focused on methods for testing low voltage cables to determine their integrity under adverse operating conditions such as a loss of coolant accident. A new method, utilizing partial discharges, is presented which has the potenti...