On-Line Application of SHEM by Particle Swarm Optimization to Grid-Connected, Three-Phase, Two-Level VSCs with Variable DC Link Voltage
نویسندگان
چکیده
منابع مشابه
Application of Particle Swarm Optimization and Genetic Algorithm Techniques to Solve Bi-level Congestion Pricing Problems
The solutions used to solve bi-level congestion pricing problems are usually based on heuristic network optimization methods which may not be able to find the best solution for these type of problems. The application of meta-heuristic methods can be seen as viable alternative solutions but so far, it has not received enough attention by researchers in this field. Therefore, the objective of thi...
متن کاملDC-DC Boost Converter with Constant Output Voltage for Grid Connected Photovoltaic Application System
The main purpose of this paper is to introduce an approach to design a DC-DC boost converter with constant output voltage for grid connected photovoltaic application system. The boost converter is designed to step up a fluctuating solar panel voltage to a higher constant DC voltage. It uses voltage feedback to keep the output voltage constant. To do so, a microcontroller is used as the heart of...
متن کاملHarmonic Elimination in Three-Phase Voltage Source Inverters by Particle Swarm Optimization
This paper presents accurate solutions for nonlinear transcendental equations of the selective harmonic elimination technique used in three-phase PWM inverters feeding the induction motor by particle swarm optimization (PSO). With the proposed approach, the required switching angles are computed efficiently to eliminate low order harmonics up to the 23 from the inverter voltage waveform, wherea...
متن کاملActive/Reactive Power Control of Three Phase Grid Connected Current Source Boost Inverter Using Particle Swarm Optimization
The future is for sustainable energy (SE) sources [1, 2]. However, to utilize SE sources efficiently one needs to integrate them into the AC Power-Grid. To do so, interface electronic circuits are needed to connect SE sources to local loads or directly to the utility grid. These interfaces are known as the SE-Grid inverters. SE-Grid inverters convert direct current (DC) to alternating current (...
متن کاملHarmonic Suppression Using On-Line Particle Swarm Optimization Based Three-Phase Shunt Active Power Filter
The harmonics due to using of nonlinear industry loads based on power electronic elements have resulted in enormous economic loss. Therefore, the power utilities always need new technologies to deal with the harmonic problems. Active power filter (APF) has been considered as an attractive solution due to its effective performance for harmonic mitigation. The compensation currents injected by th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electronics
سال: 2018
ISSN: 2079-9292
DOI: 10.3390/electronics7080151