On-chip Cellular Force Measurement Using Direct-outer-drive Mechanism
نویسندگان
چکیده
منابع مشابه
Direct Measurement of Lateral Force Using Dual Cantilevers
We have constructed an experimental system to measure a piconewton lateral force using dual cantilevers which cross with each other. The resolution of the lateral force is estimated to be 3.3 p ± 0.2 pN, which is comparable to forces due to thermal fluctuation. This experimental apparatus works so easily that it will enable us to determine forces during nano-manipulation and nano-tribological m...
متن کاملAnalysis and Design of a Permanent-Magnet Outer-Rotor Synchronous Generator for a Direct-Drive Vertical-Axis Wind Turbine
In Permanent-Magnet Synchronous Generators (PMSGs) the reduction of cogging torque is one of the most important problems in their performance and evaluation. In this paper, at first, a direct-drive vertical-axis wind turbine is chosen. According to its nominal value operational point, necessary parameters for the generator is extracted. Due to an analytical method, four generators with differen...
متن کاملDirect Force Measurement of Liposomes by Atomic Force Microscopy
Liposomes serve as models for cells and show increasing applications in medical and nonmedical fields. Unilamellar vesicles are prepared from multilamellar vesicle (MLV) dispersions either by sonication or extrusion. The shape stability of liposomes is important in the understanding of membrane fusion, as well as in drug delivery and gene therapy. Therefore it has been the subject of numerous t...
متن کاملUsing Performance Measurement to drive
The performance measurement revolution started in the late 1970s and early 1980s with the dissatisfaction of traditional backward looking accounting systems. Since then, there has been constant development in this field. If we look back and see “What is Performance Measurement?” According to Neely et al (1995), Performance Measurement is the process of quantifying effectiveness and efficiency o...
متن کاملImpedance based DNA chip for direct T(m) measurement.
Si/SiO(2) chips were used to detect the hybridization of immobilized Oligo d(T)(20) through impedance measurement. The immobilization procedure involved an aminopropyl silane grafted silicon oxide surface activated by glutaraldehyde and subsequently modified by an aminolinker supporting oligonucleotides. The immobilization procedure was optimized and, in the best conditions, the hybridization o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Society of Instrument and Control Engineers
سال: 2015
ISSN: 0453-4654,1883-8189
DOI: 10.9746/sicetr.51.2