PURPOSE To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft contact lenses (CLs). METHODS One eye each in 21 subjects was studied. The cornea was photographed usin...
متن کاملNon-contact tonometry in the postoperative eye.
The Keeler Pulsair non-contact tonometer was compared with the Goldmann applanation tonometer in a series of 48 eyes after operation. A correlation coefficient of 0.92 (p less than 0.001) was found between the two instruments, with the Pulsair having a statistically significant tendency to overread the Goldmann slightly in this situation. The Pulsair was, however, shown to be effective in the i...
متن کاملLimitations of the ocular wavefront correction with contact lenses
We analyze theoretically, by means of both computer simulations and laboratory experiments, the limitations of correcting aberrations with ideal customized contact lenses. Four experiments are presented: In the first one, we have analyzed the limitations of a static correction on the dynamic wavefront. In the second one, we studied the rotations of a contact lens on the eye using an optical met...
متن کاملIntraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry
BACKGROUND The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted D...
متن کاملTear film surface quality with rigid and soft contact lenses.
OBJECTIVES The aim of this study was to measure tear film surface quality (TFSQ) using dynamic high-speed videokeratoscopy during short-term (8 hrs) use of rigid and soft contact lenses. METHODS A group of 14 subjects wore 3 different types of contact lenses on 3 different nonconsecutive days (order randomized) in 1 eye only. The subjects were screened to exclude those with dry eye. The lense...