Occupational Radition Dose of Personal in Pediatric Interventional Cardiology

نویسندگان

چکیده

This study aimed to determine the effective doses of cardiologist, nurses, and technical staff in pediatric angiography laboratory during their diagnostic therapeutic applications. also compares radiation dose applications performed country with exposed on a world scale. A total 39 coronary (CA) + percutaneous transluminal angioplasty (PTCA) methods were study. The received for each person single application was determined, values measured sequential If annual workload is taken into consideration, it calculated that high may be 1384.7 μSv per year. Furthermore, from values, procedure range 6.5 11.1 μSv. These results are consistent literature.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent advances in pediatric interventional cardiology

During the last 10 years, there have been major technological achievements in pediatric interventional cardiology. In addition, there have been several advances in cardiac imaging, especially in 3-dimensional imaging of echocardiography, computed tomography, magnetic resonance imaging, and cineangiography. Therefore, more types of congenital heart diseases can be treated in the cardiac catheter...

متن کامل

Occupational health risks in interventional cardiology: expected inherent risk or preventable personal liability?

SEE PAGE 616 A lthough advances have been made in the diagnosis of and therapy for cardiovascular disease, this has not come without risks. This risk includes a 3-fold increase in patient medical radiation exposure over the past 25 years (1), with all imaging areas challenged to reduce patient dose (2). Although interventional cardiology contributes a small component to this increase, when a cu...

متن کامل

Evaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran

Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...

متن کامل

Occupational Eye Lens Dose in Interventional Radiology and Cardiology: New Insights

The advances in digital imaging and the improvement in interventional tools and devices like catheters and stents have expanded the use of interventional procedures. During the period 1998-2008, the total number of interventional procedures increased by 78% [1]. Interventional radiology [IR] and cardiology [IC] procedures deliver high radiation doses both to patients and medical personnel, whic...

متن کامل

Evaluation of occupational and medical dose on interventional cardiology procedures by Monte Carlo method

A cardiologia intervencionista é um conjunto de procedimentos médicos que tem como principal foco diagnosticar e tratar pacientes com problemas cardiovasculares. Embora o uso dos raios X neste caso seja justificado, é de grande importância fazer uma avaliação das doses tanto nos pacientes quanto nos profissionais envolvidos, pois as doses podem ser altas, uma vez que, na maioria dos casos, os p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of engineering technology and applied sciences

سال: 2023

ISSN: ['2548-0391']

DOI: https://doi.org/10.30931/jetas.1147340