OC-0609: Patient specific plan QA for clinical trial EORTC 1219 using Knowledge-Based Planning

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pixel response‐based EPID dosimetry for patient specific QA

Increasing use of high dose rate, flattening filter free (FFF), and/or small-sized field beams presents a significant challenge to the medical physics community. In this work, we develop a strategy of using a high spatial resolution and high frame rate amorphous silicon flat panel electronic portal imaging device (EPID) for dosimetric measurements of these challenging cases, as well as for conv...

متن کامل

Using Syntactic Knowledge for QA

We describe our system for the monolingual Dutch and multilingual English to Dutch QA tasks. First, we give a brief outline of the architecture of our QA-system, which makes heavy use of syntactic information. Next, we describe the modules that were improved or developed esepcially for the CLEF tasks, i.e. (1) incorporation of syntactic knowledge in the IR-engine, (2) incorporation of lexical e...

متن کامل

Reproducibility in patient‐specific IMRT QA

The purpose of this study was to determine the reproducibility of patient-specific, intensity-modulated radiation therapy (IMRT) quality assurance (QA) results in a clinical setting. Six clinical patient plans were delivered to a variety of devices and analyses, including 1) radiographic film; 2) ion chamber; 3) 2D diode array delivered and analyzed in three different configurations (AP deliver...

متن کامل

Anatomy‐based, patient‐specific VMAT QA using EPID or MLC log files

In this project, we investigated the use of an electronic portal imaging device (EPID), together with the treatment planning system (TPS) and MLC log files, to determine the delivered doses to the patient and evaluate the agreement between the treatment plan and the delivered dose distribution. The QA analysis results are presented for 15 VMAT patients using the EPID measurements, the ScandiDos...

متن کامل

Characterization of cylindrical ionization chambers for patient specific IMRT QA

Proven conventional dosimetry techniques do not provide accuracy and precision in the measurement of inverse planned intensity modulated radiation therapy (IMRT) fields. Dynamic and step-and-shoot multileaf collimation (DMLC/SMLC) challenge current ionization chamber dosimetry practices. Ionization chamber performance in these fields is evaluated for three cylindrical chambers of varying volume...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2018

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(18)30919-8