OC-0413: 4DCT and VMAT for lung patients with irregular breathing: Phase vs. amplitude binning
نویسندگان
چکیده
منابع مشابه
the past hospitalization and its association with suicide attempts and ideation in patients with mdd and comparison with bmd (depressed type) group
چکیده ندارد.
Scale Invariant Feature Transform with Irregular Orientation Histogram Binning
The SIFT (Scale Invariant Feature Transform) descriptor is a widely used method for matching image features. However, perfect scale invariance can not be achieved in practice because of sampling artefacts, noise in the image data, and the fact that the computational effort limits the number of analyzed scale space images. In this paper we propose a modification of the descriptor’s regular grid ...
متن کامل4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung.
Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process. Resulting treatment plans synchronize the delivery of each beam aperture to a specific ph...
متن کاملAmplitude-based gated phase-controlled rescanning in carbon-ion scanning beam treatment planning under irregular breathing conditions using lung and liver 4DCTs
Amplitude-based gating aids treatment planning in scanned particle therapy because it gives better control of uncertainty with the gate window. We have installed an X-ray fluoroscopic imaging system in our treatment room for clinical use with an amplitude-based gating strategy. We evaluated the effects of this gating under realistic organ motion conditions using 4 DCT data of lung and liver tum...
متن کاملAmplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter‐free VMAT delivery
The purpose of this study was to investigate amplitude gating combined with a coached breathing strategy for 10 MV flattening filter-free (FFF) volumetric-modulated arc therapy (VMAT) on the Varian TrueBeam linac. Ten patient plans for VMAT SABR liver were created using the Eclipse treatment planning system (TPS). The verification plans were then transferred to a CT-scanned Quasar phantom and d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2018
ISSN: 0167-8140