OC-0191 MLC-tracking latencies on Elekta Unity
نویسندگان
چکیده
منابع مشابه
Detailed analysis of latencies in image-based dynamic MLC tracking.
PURPOSE Previous measurements of the accuracy of image-based real-time dynamic multileaf collimator (DMLC) tracking show that the major contributor to errors is latency, i.e., the delay between target motion and MLC response. Therefore the purpose of this work was to develop a method for detailed analysis of latency contributions during image-based DMLC tracking. METHODS A prototype DMLC trac...
متن کاملAn Efficient Object Tracking Method on Quad-/Oc-Trees
We introduce a fast error-free tracking method applicable to sequences of two and three dimensional images. The core idea is to use Quadtree (resp. Octree) data structures for representing the spatial discretization of an image in two (resp. three) spatial dimensions. This representation enables one to merge into large computational cells the regions that can be faithfully described with such a...
متن کاملDynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback
Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...
متن کاملReal-time dynamic MLC tracking for inversely optimized arc radiotherapy.
BACKGROUND AND PURPOSE Motion compensation with MLC tracking was tested for inversely optimized arc radiotherapy with special attention to the impact of the size of the target displacements and the angle of the leaf trajectory. MATERIALS AND METHODS An MLC-tracking algorithm was used to adjust the MLC positions according to the target movements using information from an optical real-time posi...
متن کاملIMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking
The problem addressed here was to obtain optimal and deliverable dynamic multileaf collimator (MLC) leaf sequences from four-dimensional (4D) geometries for dynamic MLC tracking delivery. The envisaged scenario was where respiratory phase and position information of the target was available during treatment, from which the optimal treatment plan could be further adapted in real time. A tool for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2019
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(19)30611-5