OC-0060: Workflow automation for ultrafast kilovoltage-megavoltage conebeam CT for image guided radiotherapy
نویسندگان
چکیده
منابع مشابه
A fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study
Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...
متن کاملTransductive Prostate Segmentation for CT Image Guided Radiotherapy
Accurate 3-D prostate segmentation is a significant and challenging issue for CT image guided radiotherapy. In this paper, a novel transductive method for 3-D prostate segmentation is proposed, which incorporates the physician’s interactive labeling information, to aid accurate segmentation, especially when large irregular prostate motion occurs. More specifically, for the current treatment ima...
متن کاملPeripheral dose from megavoltage cone‐beam CT imaging for nasopharyngeal carcinoma image‐guided radiation therapy
The growing use of cone-beam computed tomography (CBCT) for IGRT has increased concerns over the additional radiation dose to patients. The in-field dose of IGRT and the peripheral dose (PD) from kilovoltage CBCT (KV-CBCT) imaging have been well quantified. The purpose of this work is to evaluate the peripheral dose from megavoltage CBCT (MV-CBCT) imaging for nasopharyngeal carcinoma IGRT, to d...
متن کاملHow does CT image noise affect 3D deformable image registration for image-guided radiotherapy planning?
PURPOSE To measure the sensitivity of deformable image registration to image noise. Deformable image registration can be used to map organ contours and other treatment planning data from one CT to another. These CT studies can be acquired with either conventional fan-beam CT systems or more novel cone-beam CT techniques. However, cone-beam CT images can have higher noise levels than fan-beam CT...
متن کاملNovel workflow for image-guided gamut mapping
bstract. We introduce a novel workflow that will hopefully open ew directions of processing and improvement in image reproducion. Existing gamut mapping algorithms can be classified into two asic categories: image-independent algorithms and imageependent algorithms. The latter algorithms produce better reprouction; however, because they are time consuming and mathematially complex, the image-in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2013
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(15)32366-5