Observing implantable collamer lens dislocation by panoramic ultrasound biomicroscopy
نویسندگان
چکیده
منابع مشابه
In Vivo Positional Analysis of Implantable Collamer Lens Using Ultrasound Biomicroscopy
Purpose. To evaluate the anterior segment, the anatomical position of the implantable collamer lenses (ICL), and its relationship to adjacent ocular structures using Ultrasound Biomicroscopy (UBM). Methods. In a prospective study, 142 myopic eyes of 93 patients implanted with Visian ICL were subjected to UBM examination between March 2010 and January 2015. The relative position of ICL to the ad...
متن کاملMeasurement of the crystalline lens radius with artemis very high frequency ultrasound biomicroscopy for implantable collamer lens sizing.
To the Editor: In their recent article, Reinstein et al.1 described the use of the Artemis 2 very high frequency digital ultrasound (ArcScan, Inc., Morrison, CO) to calculate the fit of the Visian Implantable Collamer Lens (ICL). Another parameter previously proposed as influencing ICL vaulting is the crystalline lens anterior radius of curvature (ALR).2 The ALR has not yet been used in any pre...
متن کاملSpontaneous Rotation of a Toric Implantable Collamer Lens
We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with -7.75 -4.25 × 0° and -8.25 -5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the l...
متن کاملImplantable Collamer Lens - Morphological changes induced in the anterior segment
RESULTS: The mean vault values after the first month were 349.93 μm. They remained stable during the first 24 months of the follow-up period, with a slight tendency to decrease at 36 months which was not statistically significant. We observed a reduction in the anterior chamber angle, depth and volume of 14.23°, 167 μm and 60.44 mm3, respectively. This reduction remained stable during the follo...
متن کاملMore Than a Decade of Experience With Implantable Collamer Lens.
We read with great interest the article by Moya et al. in the August 2015 issue.1 The literature on longterm outcomes and complications of posterior chamber phakic intraocular lenses is scarce and the authors effectively describe their 12-year experience with implantable collamer lens (ICL) implantation. We reviewed 349 eyes of 216 patients, of which 155 (44.4%) were treated with spheric ICLs a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Eye
سال: 2015
ISSN: 0950-222X,1476-5454
DOI: 10.1038/eye.2014.336