Observing Chaotic Oscillations Induced by under Load Tap Changer in Power Systems

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Solid-State on Load Distribution Transformer Tap-Changer on Power Quality Enhancement

Recently electronic tap-changer has received more attention due to its quick response, better performance and simpler maintenance compared to the mechanical tap-changer. This paper presents the capability of the distribution transformer equipped with an electronic tap-changer for improving power quality. At this end, the analytical computation for determining the compensating limit of electroni...

متن کامل

Innovative Transformer Load Tap Changer Control Using Ethernet-Based Communications

This paper describes the design of a load tap changer (LTC) control for up to four parallel transformers using a modified circulating current approach. The LTC control discussed in this paper was implemented using programmable logic, math functions, and IEC 61850 communications over fiber-optic Ethernet. One LTC control is associated with each transformer. The current angle from each LTC contro...

متن کامل

Solid - State On Load Tap - Changer for Transformer Using Microcontroller

The on-load tap changing (OLTC) regulators have been widely used since the introduction of electrical energy. They ensure a good regulation of the output voltage in presence of large variations of the input voltage with typical response time from several mili-seconds to several seconds. Earlier mechanical type of on load tap changers were into practice. But they had considerable limitations and...

متن کامل

Thermal model of oil power transformers with a tap changer

The paper presents a new method for on-line temperature calculation taking into account change in the tap changer position. The method introduces accurate calculation of the losses, depending on the current, average temperature of the winding, and tap changer position (it affects both Joules (DC) losses and stray losses). The thermal model itself is the common three-body model (for a transforme...

متن کامل

Improvement of on-load tap changer performance in voltage regulation of MV distribution systems with DG units using D-STATCOM

This paper presents a new technique for the voltage regulation of a radial medium voltage (MV) distribution grid in presence of distributed generation (DG) units. The proposed technique consists of the coordinated action of on-load tap changer (OLTC) of transformer and reactive power compensation by D-STATCOM. Managing the system voltage using the action of OLTC is one of the most common ways f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Sciences

سال: 2006

ISSN: 1812-5654

DOI: 10.3923/jas.2007.66.71