Observation of dose-rate dependence in a Fricke dosimeter irradiated at low dose rates with monoenergetic X-rays
نویسندگان
چکیده
منابع مشابه
Verification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams
Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...
متن کاملFricke gel dosimeter with improved sensitivity for low‐dose‐level measurements
Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue-equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, independence of dose rate and incident direction, as well as linear dose response. This work presents the development and characteri...
متن کاملPerformance of Sife - Eldeen dosimeter over broad absorbed dose and dose rate ranges of γ – radiation and at different temperatures
Background: Results are presented on some dosimetric characteristics of Sife – Eldeen dosimeter based on the radiation induced conductivity (RIC) of 3.5 M aqueous urea solutions. The studied characteristics were the response (RIC) of Sife – Eldeen dosimeter in broad ranges of absorbed dose, dose rates and at different irradiation temperature. Materials and Methods: Kent EIL5007 conductivity met...
متن کاملverification of dose rate and energy dependence of magica polymer gel dosimeter with electron beams
background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...
متن کاملEvaluation of low dose diagnostic X-rays induced effect on the white blood cells count in Guinea pigs
Background: Exposure to ionizing radiation is known to have various effects on hematological parameters of biological sample. This study was aimed at evaluating the effect of ionizing radiation on some hematological parameters in guinea pigs. Materials and Methods: Thirty-six (36) apparently healthy adult guinea pigs of both sexes weighing between 700g – 1200...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2018
ISSN: 2045-2322
DOI: 10.1038/s41598-018-21813-z