OBSERVABILITY AND REDUNDANCY BASED PMU PLACEMENT AT OPTIMAL LOCATION OF POWER SYSTEM
نویسندگان
چکیده
منابع مشابه
Optimal Multistage Scheduling of Pmu Placement for Power System Observability
The standards of power system monitoring, control and protection are elevated by Phasor Measurement Units (PMUs) as an auspicious tool. It is the purpose of this paper to determine the optimal number and locations of PMUs so as to make the system measurement model observable and also estimate the power system state. The proposed modelling approach which models PMU placement as an integer linear...
متن کاملAn optimal PMU placement technique for power system observability
0142-0615/$ see front matter 2012 Elsevier Ltd. A http://dx.doi.org/10.1016/j.ijepes.2012.03.011 ⇑ Corresponding author. E-mail address: [email protected] (B.K. Saha Roy Power system state estimation with exclusive utilization of synchronous phasor measurements demands that the system should be completely observable through PMUs only. To have minimum number of PMUs, the PMU placement issue in an...
متن کاملOptimal PMU Placement in Power System Considering the Measurement Redundancy
In this paper, Integer Programming based methodology is presented for the optimal placement of Phasor Measurement Unit (PMU) that minimizes the cost of installation and provide the entire power system observability. The concepts of zero injection buses are used in this paper for further reduction in number of PMUs. Integer Programming may produce multiple results if neighboring buses to zero in...
متن کاملObservability of power systems with optimal PMU placement
Phasor Measurement Units (PMUs) are measuring devices that, when placed in electrical networks, observe their state by providing information on the currents in their branches (transmission lines) and voltages in their buses. Compared to other devices, PMUs have the capability of observing other nodes besides the ones they are placed on. Due to a set of observability rules, depending on the plac...
متن کاملObservability-Enhanced PMU Placement Considering Conventional Measurements and Contingencies
Phasor Measurement Units (PMUs) are in growing attention in recent power systems because of their paramount abilities in state estimation. PMUs are placed in existing power systems where there are already installed conventional measurements, which can be helpful if they are considered in PMU optimal placement. In this paper, a method is proposed for optimal placement of PMUs incorporating conve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES
سال: 2019
ISSN: 0973-8975,2454-7190
DOI: 10.26782/jmcms.2019.12.00044