Objective autorefraction in posterior chamber pseudophakia.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Objective autorefraction in posterior chamber pseudophakia.

Automated refraction with the Canon RK-1 Autoref keratometer was evaluated in 110 eyes (110 patients) six to eight weeks after they had undergone extracapsular cataract extraction with posterior chamber intraocular lens implantation and achieved a best corrected visual acuity of at least 6/12. Autorefraction readings were obtained in 100 (91%) of these eyes. The agreement between autorefraction...

متن کامل

Clinical evaluation of automated refraction in anterior chamber pseudophakia.

Automated refraction with the Canon RK-1 Autoref keratometer was evaluated in 85 eyes of 85 patients with an anterior chamber intraocular lens implant and a best corrected visual acuity of at least 6/12. Autorefraction readings were obtained in 80 (94%) of these eyes. The agreement between autorefraction and clinical refraction data was 89% for spherical equivalence less than 0.51 dioptres (D),...

متن کامل

Recreating the Posterior Chamber Lens

T he history of IOLs began in 1949 with Sir Harold Ridley’s insertion of an artificial lens into the posterior chamber. Although placing an IOL within the space from which the cataract had been removed seemed (and seems still) a natural, almost obvious choice, ophthalmologists abandoned posterior chamber lens implantation within a few years. I reawakened surgeons’ interest in posterior chamber ...

متن کامل

Hydrostatic Approach to Posterior Chamber

at operation, rather than rely on spontaneous leakage (if this ever occurs) or absorption in the few days immediately following operation. A view of the fundus on the day after operation bears out this supposition in most cases, and in some it would be difficult to tell, except for the area of coagulation, that there had been a detachment present at all, owing to the entire absence of folds or ...

متن کامل

Colour perception in pseudophakia.

Minor differences in colour perception between pseudophakic, phakic, and spectacle aphakic eyes were identified by the Pickford-Nicholson anomaloscope and the Farnsworth-Munsell 100-hue test. The results suggest that pseudophakic eyes are more sensitive to red and less sensitive to blue than aphakic eyes corrected with spectacles. Spectrophotometer measurements reveal that the Rayner-Pearce pos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Ophthalmology

سال: 1990

ISSN: 0007-1161

DOI: 10.1136/bjo.74.12.731