Nyquist Stability Analysis of an AC-Grid Connected VSC-HVDC System Using a Distributed Parameter DC Cable Model

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nyquist stability analysis of a VSC-HVDC system using a distributed parameter DC-cable model

In this paper a two terminal VSC-HVDC system embedded in a strong grid ACenvironment is considered, emphasizing modeling, controllers design and small-signal stability analysis. Traditionally, DC cables are most often modeled by Π-sections, and when using them for higher frequencies or in case of transmission over long distances, approximation accuracy aspects must be considered. Here, a distri...

متن کامل

Voltage Stability Bifurcation Analysis for AC / DC Systems with VSC - HVDC

and Applied Analysis 3 3. Voltage Stability Model for AC/DC Systems with VSC-HVDC 3.1. The Modified Power Flow Algorithm Based on Sequential Iteration Method. For the previous model of AC/DC system with VSC-HVDC, the simplified power flow equations are given by fac = 0, fac-dc = 0, fdc = 0, (7) where fac = [ΔPa1, ΔQa1, . . . , anAC , anAC T, fac-dc = [ΔPt1, ΔQt1, . . . , tnVSC , tnVSC ] T, fdc ...

متن کامل

Controllers For A VSC-HVDC Link Connected To A Weak AC System

In this paper, the interconnection of a strong AC system to a weak AC system by using a Voltage Source Converter (VSC) based High Voltage DC (HVDC) transmission system is investigated. In this work, the weak AC system considered is an island system comprised of synchronous generators and passive load. Analysis is carried out for UPF load and inductive load. The ac filter requirement to achieve ...

متن کامل

DC Impedance-Model-Based Resonance Analysis of a VSC-HVDC System

Resonances can have negative impact on a Voltage Source Converter-High Voltage DC (VSC-HVDC) system. This paper develops dc impedance models for the rectifier and inverter stations for a VSC-HVDC system when they are viewed from a dc terminal. The impedance models take converter controllers into account. The derived impedance models are validated by comparing frequency responses of the analytic...

متن کامل

A novel control method for a VSC-HVDC system in a grid-connected wind farm

The voltage source converter-high voltage direct current (VSC-HVDC) transmission is the ideal integration technology for grid-connected wind farms. A passivity-based control (PBC) method for VSC-HVDC when the wind farm voltage is unbalanced is proposed in this paper. The mathematical model of a VSC with unbalanced voltage is established. The PBC theory including dissipation inequality and syste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Delivery

سال: 2016

ISSN: 0885-8977,1937-4208

DOI: 10.1109/tpwrd.2015.2501459