Numerical Study on Transverse Temperature Distribution of Fire Zone in Metro Tunnel Fire

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of Metro Train Fire in an Underground Station of Tehran Metro Line 7

In this research a fire scenario was simulated in one of the stations of the line 7 of Tehran's subway system. The Line 7 is under construction and the ventilation system is under design. Fire was set for a stopping metro train at the platform of the station. A 160 meter length eight-car metro train with the forth wagon on the fire was studied. The heat release rate is based on a quadratic f...

متن کامل

Numerical Simulation of Water Mist Suppression of Tunnel-fire Scenarios

Water-mist fire suppression systems offer a number of potential advantages over conventional sprinkler systems. A water-mist system uses very fine droplets of around 50μm diameter, which results in entirely different behaviour. In particular the water-mist remains suspended in air for long periods, and is influenced by the airflows caused by the fire and the general ventilation regime. In order...

متن کامل

Investigation of forest fire hazard areas in Golestan province based on fire risk system index (FRSI) using the technique (GIS)

Abstract  Fire in natural resources is one of the crises that causes irreparable damage to ecosystems and the environment every year. The purpose of this research is to attempt to study areas of risk aversion and to prepare a map of forest fire hazard area by integrating topographic data and other additional information from a GIS system for Golestan province. In order to carry out this resear...

متن کامل

Resolving vorticity-driven lateral fire spread using the WRF-Fire coupled atmosphere–fire numerical model

Vorticity-driven lateral fire spread (VLS) is a form of dynamic fire behaviour, during which a wildland fire spreads rapidly across a steep leeward slope in a direction approximately transverse to the background winds. VLS is often accompanied by a downwind extension of the active flaming region and intense pyro-convection. In this study, the WRF-Fire (WRF stands for Weather Research and Foreca...

متن کامل

Study on Applicability of FDS+Evac for Evacuation Modeling in Case of Road Tunnel Fire

In this study, fire in a short 2-lane single-directional road tunnel with two different traffic situations is considered and the impact of spread of fire and smoke on people evacuation is investigated. The FDS+Evac system used comprises of FDS (Fire Dynamics Simulator), an advanced CFD (Computational Fluid Dynamics) fire field model supplemented by agent-based FDS evacuation model, Evac. Evac i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Procedia Engineering

سال: 2016

ISSN: 1877-7058

DOI: 10.1016/j.proeng.2016.01.145