Numerical Simulation of Heat Extraction by a Coaxial Ground Heat Exchanger Under Freezing Conditions

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of a Domestic Ground Source Heat Pump System Using a Transient Numerical Borsehole Heat Exchanger Model

Common approaches to the simulation of Borehole Heat Exchangers (BHEs) assume heat transfer in circulating fluid and grout to be in a quasi-steady state and ignore fluctuations in fluid temperature due to transport of the fluid around the loop. However, in domestic ground source heat pump systems, the heat pump and circulating pumps switch on and off during a given hour; therefore the effect of...

متن کامل

numerical simulation of a horizontal ground-coupled heat pump

this study represents effect of four variables in performance of a heat-pump in two cities of tehran and rasht. a computer program has been developed, simulating a certain heat pump acting in different environments with different refrigerants in heating season. the analysis is based on a homogeneous model. effect of different refrigerants, depth of the buried heat exchangers and moisture conten...

متن کامل

Numerical simulation of a three-layered radiant porous heat exchanger including lattice Boltzmann simulation of fluid flow

This paper deals with the hydrodynamic and thermal analysis of a new type of porous heat exchanger (PHE). This system operates based on energy conversion between gas enthalpy and thermal radiation. The proposed PHE has one high temperature (HT) and two heat recovery (HR1 and HR2) sections. In HT section, the enthalpy of flowing high temperature gas flow that is converted to thermal radiation em...

متن کامل

Numerical Simulation and Analysis on Liquid Nitrogen Spray Heat Exchanger

Abstract—Liquid spray heat exchanger is the critical equipment of temperature regulating system by gaseous nitrogen which realizes the environment temperature in the range of -180 °C~+180 °C. Liquid nitrogen is atomized into smaller liquid drops through liquid nitrogen sprayer and then contacts with gaseous nitrogen to be cooled. By adjusting the pressure of liquid nitrogen and gaseous nitrogen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Social Science Research Network

سال: 2022

ISSN: ['1556-5068']

DOI: https://doi.org/10.2139/ssrn.4127025