In order to improve their efficiency, transcritical CO2 heat pumps need resort the use of a subcooling method. Among different methods, dedicated mechanical (DMS) systems and internal exchangers (IHX) are currently more promising technologies. This paper presents numerical study water source pump during hot generation using methods. Ten configurations, including both, IHX DMS, separately combined in layouts, some them not studied previously, analyzed numerically under same operating conditions compare performance. A description model is presented: compressors modeled performance curves provided by manufacturers, expansion valves as isenthalpic, deriving correlations for evaporation/condensation pressure transfer rate obtained 1D cell-by-cell discretization method previously applied all exchangers. Results presented heating show that most configurations analyzed, DMS does system compared base with IHX. There only an improvement efficiency two those which main cycle coupled flowing first through evaporator auxiliary then gas cooler cycle. Specifically, IHX, configuration provides best results (Conf. F* according nomenclature used this work) gives average improvements around 26% almost 160% capacity, while optimum reduced 12%. Even more, other authors (indirect without Conf. F improves 8.5%, decrease total capacity lower than 1% similar pressure. The also compressor way distributed among have important influence on system, although depends studied. For F*), when (55% comes from cycle), mostly heated (85% flow condenser cycle, 15% cycle).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field Evaluation for Air-source Transcritical CO2 Heat Pump Water Heater with Optimal Pressure Control

Several optimal discharge pressure correlations for transcritical CO2 heat pump in literature have been discussed in this paper. Most of them are related to the ambient temperature, the evaporation temperature and the gas cooler outlet temperature. A revised optimal discharge pressure model as the function of ambient temperature and water outlet temperature is developed based on earlier experim...

متن کامل

Performance of a Transcritical CO2 Heat Pump for Simultaneous Water Cooling and Heating

This paper presents the experimental as well as the simulated performance studies on the transcritical CO2 heat pumps for simultaneous water cooling and heating; effects of water mass flow rates and water inlet temperatures of both evaporator and gas cooler on the cooling and heating capacities, system COP and water outlets temperatures are investigated. Study shows that both the water mass flo...

متن کامل

Performance study on solar assisted heat pump water heater using CO2 in a transcritical cycle

This study reports the numerical analyses of a CO2 transcritical cycle on solar assisted heat pump water heating system in which evacuated tube U-pipe solar collector is utilized as an evaporator. This simulation model can predict operating characteristics for moderate meteorological conditions of North Dakota. The main purpose of this work is to simulate the overall performance of the heat pum...

متن کامل

Influence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO2 Heat Pump Water Heater

Besides compressor rotary speed and parameters of water flowing through gas cooler and evaporator, refrigerant charge amount and electronic expansion valve (EEV) opening are two important parameters that have significant effects on the performance of a transcritical CO2 heat pump system. In this study, the effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump ...

متن کامل

Experimental Study on the Performance of Water Source Trans-Critical CO2 Heat Pump Water Heater

The effect of the discharge pressure on the performance of the trans-critical CO2 heat pump with a low gas-cooler outlet temperature is experimentally investigated on a test rig of water source heat-pump water heater. The optimal discharge pressure of the trans-critical CO2 heat pump is investigated under different external operation conditions. When the tap-water temperature is low, the charac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied Thermal Engineering

سال: 2023

ISSN: ['1873-5606', '1359-4311']

DOI: https://doi.org/10.1016/j.applthermaleng.2022.119639