This paper presents a numerical model of an integrated 3D casing-cement-formation system, to evaluate the mechanical tensile and shear failure cement at casing-cement interface as pressure temperature conditions formation borehole vary during production. The which includes pressure, unlike others proposed, was developed by stages under finite element discretization compared analytical models. Results show that increasing increases probability in cement, while wellbore decreases these probabilities. On other hand, decrease well reduces failure. In case opposite occurs.
منابع مشابه
Cement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration
Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term im...
متن کاملFailure of the cement-bone interface.
We report the early failure, at a mean of 37 months, of 17 femoral prostheses due to aseptic loosening at the cement-bone interface. In every case the prosthesis had been manufactured with a surface coating designed to enhance the strength of the cement-prosthesis interface. It is postulated that improving the bond at the cement-prosthesis interface may transfer increased stress to the cement-b...
متن کاملCreep dominates tensile fatigue damage of the cement-bone interface.
Fatigue damage from activities of daily living has been considered to be a major cause of aseptic loosening in cemented total hip arthroplasty. The cement-bone interface is one region where loosening could occur, but to date the fatigue response of the interface has not been examined. Cement-bone specimens were prepared from fresh frozen human cadaver tissue using simulated in vivo conditions. ...
متن کاملPorosity reduction in bone cement at the cement-stem interface.
The fatigue failure of bone cement, leading to loosening of the stem, is likely to be one mode of failure of cemented total hip replacements. There is strong evidence that cracks in the cement are initiated at voids which act as stress risers, particularly at the cement-stem interface. The preferential formation of voids at this site results from shrinkage during polymerisation and the initiati...
متن کاملRisk Assessment of Occupational Exposure to Cement Respirable Particles and Crystalline Silica in a Cement Factory
Introduction: Cement factory workers exposure to airborne particles containing crystalline silica in Portland cement chemical compound can caused pulmonary diseases, including silicosis and lung cancer. The aim of this study was to assess the risk of occupational exposure to respirable cement dust and crystalline silica in a cement factory in Khorasan Razavi province. Methods: In this cross-se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Dyna-colombia
سال: 2022
ISSN: ['0012-7353', '2346-2183']
DOI: https://doi.org/10.15446/dyna.v89n221.98464