NUMERICAL INVESTIGATION OF THE COLD FORMED STEEL PROFILES BOLTED JOINTS
نویسندگان
چکیده
منابع مشابه
Structural behavior of cold-formed stainless steel bolted connections
This paper presents a series of tests on cold-formed stainless steel bolted connections. The test specimens were fabricated from three different types of stainless steel, including austenitic stainless steel EN1.4301 (AISI 304) and EN1.4571 (AISI 316Ti having small amount of titanium) as well as lean duplex stainless steel EN1.4162 (AISI S32101). The material properties of the three types of st...
متن کاملFinite Element Analysis on Tensile Stiffness of Cold-Formed Steel Bolted Connections
This paper presents a finite element analysis on the tensile stiffness of steel bolted connections, which are fabricated from thin-walled cold-formed steel strips and members. This type of bolted connection is usually used to assemble the diagonal bracing member in the light steel structure. Unlike the architectural steel structure, thin walled steel bolted connection cannot be simplified into ...
متن کاملExperimental Investigation on Cold-formed Steel Wall Plate System
A series of tests on cold-formed steel (CFS) wall plate system subjected to uplift force at the mid span of the wall plate is presented. The aim of the study was to study the behaviour and identify the modes of failure of CFS wall plate system. Two parameters were considered in these studies: 1) different dimension of U-bracket at the supports and 2) different sizes of lipped Cchannel. The lipp...
متن کاملOn Cold-Formed Steel Construction
Powder-actuated (also referred to as low velocity or powder-driven) fasteners are commonly used to attach cold-formed steel framing members, usually a track, to a concrete or structural steel support. Although commonly used, their behavior is less well understood than other fasteners such as screws, bolts and welds. The AISI Cold-Formed Steel Design Manual does not explicitly address powder act...
متن کاملExperimental and Numerical Study on Single-Bolted Cold-Formed Angles under Tension and Compression
Angle sections are commonly designed to bear only axial force, usually neglecting the additional bending moments resulting from the eccentric connection and the shift of the effective centroid. The current work deals with the capacity of single-bolted equal angle sections made from cold-formed steel. The experimental investigation presented herein includes tension and compression tests that sub...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Zbornik radova Građevinskog fakulteta
سال: 2017
ISSN: 0352-6852,2334-9573
DOI: 10.14415/konferencijagfs2017.025