Numerical Characterization of the Flow Dynamics and COP Estimation of a Binary Fluid Ejector Ground Source Heat Pump Cooling System

نویسندگان

چکیده

Ejector-based refrigeration systems can make direct use of many forms thermal energy, such as solar thermal, waste heat, biogas, or natural gas. The present paper describes the estimation coefficient performance (COP) a binary fluid ejector ground source heat pump (BFE GSHP) cooling system. A method for selection was defined based on favorable thermo-physical properties working fluids. short list pairs were selected their BFE GSHP Computational Fluid Dynamics (CFD) investigation conducted and suitable geometry is proposed high compression ratios encountered in applications. mixing between primary secondary fluids investigated using physical analysis CFD results. effect fluids’ system also discussed.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining the optimal size of a ground source heat pump within an air-conditioning system with economic and emission considerations

One of the most challenging issues in modern-day building energy management involves equipping the buildings with more energy efficient facilities. In this paper, a hybrid system for cooling/heating for a residential building is developed and optimized. The system consists of a ground source heat pump (GSHP) as well as an electric chiller (EC) and boiler. The model is implemented in MATLAB ...

متن کامل

Heat exchanger technology and applications: ground source heat pump system for buildings heating and cooling

The earth’s surface acts as a huge solar collector, absorbing radiation from the sun. In the UK, the ground maintains a constant temperature of 11-13oC several metres below the surface all the year around.1 Among many other alternative energy resources and new potential technologies, the ground source heat pumps (GSHPs) are receiving increasing interest because of their potential to reduce prim...

متن کامل

تأثیر نوع سیال عامل بر عملکرد سیستم تبرید اجکتوری

In this paper, the performance of an ejector cooling system and the effect of the following different working fluids such as water, ammonia, R134a, R141b, R12, R600 and R245fa are described and the effects of cycle parameters on the consumed heat and work and COP are studied. This cycle with the working fluid R141b has the least COP while the working fluid R₁₂ in comparison with the other worki...

متن کامل

Performance Assessment of a Variable Capacity Air Source Heat Pump and a Horizontal Loop Coupled Ground Source Heat Pump System

This study evaluates the performance of air source heat pump (ASHP) and ground source heat pump (GSHP) systems individually and as part of their associated heating and cooling distribution systems in two semi-attached houses. Over the monitoring period, the performance of both heat pumps exceeded manufacturer and EnerGuide ratings, with Coefficients of Performance (COPs) above 5 in the cooling ...

متن کامل

numerical simulation of a horizontal ground-coupled heat pump

this study represents effect of four variables in performance of a heat-pump in two cities of tehran and rasht. a computer program has been developed, simulating a certain heat pump acting in different environments with different refrigerants in heating season. the analysis is based on a homogeneous model. effect of different refrigerants, depth of the buried heat exchangers and moisture conten...