Numerical calculation of relative dose rates from spherical 106 Ru beta sources used in ophthalmic brachytherapy

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources

Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...

متن کامل

Beta and gamma dose rates from terrestrially distributed sources.

Dose rates in air and at various depths in tissue produced by concentrations of natural isotopes in the ground are calcu lated for both beta and gamma radiation. Calculated gonadal "screening factors" are within k$ of the experimental values reported by the British Medical Research Council*

متن کامل

monte carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with cobalt-60 sources

background: in the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using monte carlo (mc) method. materials and methods: two 60co sources of gzp6 brachytherapy unit used for intracavitary treatments were simulated using mcnpx monte carlo code. also the two types of colpostats including shielded and unshielded were simulated inside ...

متن کامل

Traceability to Absorbed-dose-to-water Primary Standards in Dosimetry of Brachytherapy Sources Used for Radiotherapy

− In the current brachytherapy practice, the procedures to determine the absorbed dose imparted to the patient are affected by an uncertainty higher than in radiotherapy with external beams. That could reduce the success of brachytherapy treatments. Most of the uncertainty is due to a lacking metrology: no absorbed-dose primary standards are so far available to assure direct traceability in dos...

متن کامل

Material-specific Conversion Factors for Different Solid Phantoms Used in the Dosimetry of Different Brachytherapy Sources

Introduction Based on Task Group No. 43 (TG-43U1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Results in Physics

سال: 2015

ISSN: 2211-3797

DOI: 10.1016/j.rinp.2015.02.006