Numerical Analysis Of Viscous Wall Dampers On Steel Frame
نویسندگان
چکیده
منابع مشابه
Dynamic Experiment and Numerical Simulation of a Full Scale Steel Frame with Viscous Dampers
This paper presents a dynamic nonlinear numerical simulation of a 5-story full-scale steel frame structure based on Perform-3D. Flexibility-based fiber element and Maxwell model are adopted for structure member simulation after a post analysis of the shaking table test of a 4-story full-scale steel frame. The author simulates the low cyclic reciprocating load test for the steel members with fib...
متن کاملNumerical and Experimental Assessment of Various Non-classical Methods for Parametric Identification of Nonlinear Viscous Dampers
Passive strategies based on the introduction of energy dissipating devices into the structures have received considerable attention in recent years. Within this framework, as reliable and cheap energy-dissipation devices, viscous fluid dampers have been largely used in seismic protection of industrial machines, technical equipments, buildings and bridges. Since the versatility of this passive p...
متن کاملPerformance-Based Plastic Design of Moment Frame-Steel Plate Shear Wall as a Dual System
Steel Plate Shear Wall (SPSW) is an emerging seismic load-resistant system that, compared to other systems, enjoys the advantages of stable ductile behavior, fewer detailing requirements, rapid constructability, and economy. American seismic provisions decree that a SPSW should be designed as a moment frame with a web infill plate. Specifically, in case of buildings taller than 160 ft, it decre...
متن کاملThe Effect of Viscous Dampers on Improvement of the Behavior of Tall Belt Truss Structures
Using energy absorption systems in the structures with malfunctioning components is of paramount importance. By absorbing the seismic energy, these systems help the components of the structure to remain resilient during earthquake. In the present study, viscous dampers were applied in order to enhance the reactions of tall building with belt truss. To assess the response of a structure under e...
متن کاملThe Effect of Viscous Dampers on Improvement of the Behavior of Tall Belt Truss Structures
Using energy absorption systems in the structures with malfunctioning components is of paramount importance. By absorbing the seismic energy, these systems help the components of the structure to remain resilient during earthquake. In the present study, viscous dampers were applied in order to enhance the reactions of tall building with belt truss. To assess the response of a structure un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATEC Web of Conferences
سال: 2018
ISSN: 2261-236X
DOI: 10.1051/matecconf/201814701001