Numerical Analysis of dew point Indirect Evaporative Cooler
نویسندگان
چکیده
An indirect evaporative cooler that uses a Maisotsenko (M) Cycle has the potential to be green and sustainable solution for managing building’s cooling demand since it can attain sub-wet bulb temperature without humidification. This study presents design simulation analysis of crossflow using COMSOL Multiphysics software various ambient conditions. The cooler’s performance was evaluated by varying inlet air temperatures. conducted numerical simulations, outcomes were compared with experimental data. results demonstrated could achieve significant reductions at minor energy consumption as traditional conditioning systems. delivers this system reduces up 22°C well capacity coefficient values are 3.699 kW 27.40. Overall, demonstrate coolers an energy-efficient alternative conventional
منابع مشابه
Dew-point hygrometry system for measurement of evaporative water loss in infants.
Evaporation of water from the skin is an important mechanism in thermal homeostasis. Resistance hygrometry, in which the water vapor pressure gradient above the skin surface is calculated, has been the measurement method of choice in the majority of pediatric investigations. However, resistance hygrometry is influenced by changes in ambient conditions such as relative humidity, surface temperat...
متن کاملAdvanced Analysis of Dew Point Control Unit of Hybrid Refrigeration Systems in Gas Refineries
In this paper, an advanced analysis of a novel hybrid compression-absorption refrigeration system (HCARS) for natural gas dew point control unit in a gas refinery is presented. This unit separates the heavy hydrocarbon molecules in the natural gas, which is traditionally carried out by natural gas cooling in a compression refrigeration cycle (CRS). The power input required for the refrigeration...
متن کاملDew point measurement using a sensitive circuit type of dew point sensor
Received: 13 Mar. 2012; Revised 25 Jul. 2012; Accepted 04 Aug. 2012 Received: April 8, 2012; Revised May 4, 2012; Accepted June 6, 2012 Abstract: Aiming at the problem of atmospheric humidity measurement, this paper proposes a method to measure dew point based on sensitive circuit for the first time. We use the quartz crystal in the Colpitts circuit as the humidity sensitive element. Since the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATEC web of conferences
سال: 2023
ISSN: ['2261-236X', '2274-7214']
DOI: https://doi.org/10.1051/matecconf/202338101007