Novel Scatter Compensation of List-Mode PET Data Using Spatial and Energy Dependent Corrections

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PET energy-based scatter estimation and image reconstruction with energy-dependent corrections.

In this paper we propose a comprehensive energy-based scatter correction approach for positron emission tomography (PET). We take advantage of the marked difference between the energy spectra of the unscattered and scattered photons, and use the detailed energy information that comes with the list-mode data for the estimation of the scattered events distribution in the data space. Also, inside ...

متن کامل

Continuous Time Dynamic PET Imaging Using List Mode Data

We describe a method for computing a continuous time estimate of dynamic changes in tracer density using list mode PET data. The tracer density in each voxel is modeled as an inhomogeneous Poisson process whose rate function can be represented using a cubic B-spline basis. An estimate of these rate functions is obtained by maximizing the likelihood of the arrival times of each detected photon p...

متن کامل

Online PET Reconstruction From List-Mode Data

This work proposes an alternative to ordered subsets to improve the convergence speed of list-mode expectationmaximization image reconstruction algorithms. Instead of subdividing the input data into non-overlapping subsets, the stream of measured coincidence events is immediately processed online. The reconstruction algorithm maintains a sliding window covering the events that contribute to the...

متن کامل

A scatter-corrected list-mode reconstruction and a practical scatter/random approximation technique for dynamic PET imaging.

We describe an ordinary Poisson list-mode expectation maximization (OP-LMEM) algorithm with a sinogram-based scatter correction method based on the single scatter simulation (SSS) technique and a random correction method based on the variance-reduced delayed-coincidence technique. We also describe a practical approximate scatter and random-estimation approach for dynamic PET studies based on a ...

متن کامل

Lossless Compression of List-Mode 3D PET Data

We describe lossless methods for compression of 3D PET data. Static list-mode data is re-sorted into sinograms and compressed using a combination of run-length and entropic coding. Dynamic list-mode data is compressed using a sinogram/timogram format in which the arrival times of each photon pair are stored in spatial order, indexed by the sinogram. Compression of the timogram is performed usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Medical Imaging

سال: 2011

ISSN: 0278-0062,1558-254X

DOI: 10.1109/tmi.2010.2095025