Note: Nonlinear susceptibility from high DC field torque magnetometry
نویسندگان
چکیده
منابع مشابه
Anisotropic properties of MgB2 by torque magnetometry
Anisotropic properties of superconducting MgB2 obtained by torque magnetometry are compared to theoretical predictions, concentrating on two issues. Firstly, the angular dependence of Hc2 is shown to deviate close to Tc from the dependence assumed by anisotropic Ginzburg-Landau theory. Secondly, from the evaluation of torque vs angle curves it is concluded that the anisotropy of the penetration...
متن کاملNanotesla Torque Magnetometry Using a Microcantilever
We present a novel ultrasensitive magnetometry technique using a micromachined magnetic cantilever that is brought in resonance. The induced magnetic moment generates a torque on the cantilever, thereby effectively stiffening the cantilever spring constant and changing its resonance frequency. Experiments are in good correspondence with the presented analytical model for this frequency shift, p...
متن کاملPiezoresistive cantilever designed for torque magnetometry
New piezoresistive silicon cantilevers designed specifically for torque magnetometry on microscopic samples have been microfabricated and tested. These levers have been optimized to detect the torque in two directions corresponding to flexion and torsion. Torque resolution of ;10 N m can be achieved depending on the operating mode. In one version an integrated loop allows an absolute calibratio...
متن کاملDC Magnetometry at the T2 Limit
Sensing static or slowly varying magnetic fields with high sensitivity and spatial resolution is critical to many applications in fundamental physics, bioimaging and materials science. Several versatile magnetometry platforms have emerged over the past decade, such as electronic spins associated with Nitrogen Vacancy (NV) centers in diamond. However, their high sensitivity to external fields al...
متن کاملEntanglement-based dc magnetometry with separated ions
We demonstrate sensing of inhomogeneous dc magnetic fields by employing entangled trapped ions, which are shuttled in a segmented Paul trap. As sensor states, we use Bell states of the type |↑↓〉 + e |↓↑〉 encoded in two Ca ions stored at different locations. Due to the linear Zeeman effect, the relative phase φ serves to measure the magnetic field difference between the constituent locations, wh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2014
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.4870796