Note: Development of target changeable palm-top pyroelectric x-ray tube

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Note: Development of target changeable palm-top pyroelectric x-ray tube.

A target changeable palm-top size x-ray tube was realized using pyroelectric crystal and detachable vacuum flanges. The target metals can be exchanged easily by attaching them on the brass stage with carbon tape. When silver and titanium palates (area: 10 mm(2)) were used as targets, silver Lα and titanium K lines were clearly observed by bombarding electrons on the targets for 90 s. The intens...

متن کامل

Pyroelectric Crystal-Based X-Ray Diffractometer by

We investigate the use of an Amptek Cool-X X-ray Generator for an instructional tool in the physics of x-rays, as well as a source for x-rays for crystal diffraction experiments. The x-ray source is a solid-state two-phase air-cooled source with a timevarying photon output. Two detectors are used in this experiment, the first being an Amptek X-123 Spectrometer and the second a combination scint...

متن کامل

Development of a Palm-size Electron Probe X-ray Analyzer

An electron probe microanalyzer (EPMA) with a palm-size chamber including the electron source and the sample stage was developed using a pyroelectric crystal. Energy of obtained continuous X-rays and lower limits of detection of transition metals (titanium, iron, and nickel) were evaluated. End point energy (Duane-Hunt limit) of obtained continuous X-rays was about 40 keV, but the palm-size EPM...

متن کامل

Identification of glass and ceramics by X-ray fluorescence analysis with a pyroelectric X-ray generator.

Applications of X-ray fluorescence (XRF) analysis with a pyroelectric X-ray generator are presented. Glass and ceramics were analyzed with this novel X-ray generator to examine its capability for analyzing nonmetallic inorganic material. Although the power of X-ray output was a few orders of magnitude lower than conventional X-ray tubes, many elements such as Si, K, Ca, Ti, Cr, Fe, Zn, Sr, Ba, ...

متن کامل

Evaluation of a systemic change of Superficial X-ray tube characteristics

Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Review of Scientific Instruments

سال: 2012

ISSN: 0034-6748,1089-7623

DOI: 10.1063/1.3677843