The 'Modified U' technique: a refined method of Norplant removal.
Norplant removal has been much more difficult for many physicians than might have been anticipated. Dr Untung Praptohardjo of Indonesia recently developed the "U" technique, speeding the time required to remove the six Norplant implants to an average of 7 minutes. In his technique, a unique oval-ring-tipped forceps with an internal diameter of 2.2 mm is used to reach through a 4-mm incision to ...
متن کاملLaparoscopic Removal of an Artery Forceps
Numerous foreign bodies, such as surgical gauze, pads and instruments, and other items, have been left behind in the abdominal cavity during open surgeries. These have been traditionally removed at redo open surgeries. Here we describe a case of an artery forceps left behind at a previous surgery (open cholecystectomy and appendicectomy) performed 5 years earlier that was removed by laparoscopy.
متن کاملNorplant™ Cellulitis
A 23-year-old woman presented to her gynecologist’s ofrice with a complaint of redness and tenderness at the site of her Norplan(TM, inserted 2 years prior. One week prior to presentation she had lacerated her fingertip while diving in the Bahamas (Fig. 1). Examination revealed erythema and tenderness overlying the NorplantTM site (Fig. 2). A course of orally administered trimethoprim/sulfameth...
متن کاملLaparoscopic Removal of Retained Artery Forceps Causing Internal Hernia
rarer. Retained artery forceps remain inert and induce their effects through mechanical means giving rise to pressure effects resulting in abdominal pain or direct tissue/viscous injury leading to tissue strangulation or perforation of viscous leading to for example peritonitis or vascular injury resulting in hemorrhage [1]. The clinical presentation of retained intra-abdominal foreign material...
متن کاملRemoval of broken fragment of biopsy forceps with magnetic extractor.
Transbronchial lung biopsy performed on a 51-year-old woman for the evaluation of nodular densities with cavities in the bilateral apical areas was complicated by the breakage of the biopsy forceps. The broken fragment of the forceps was successfully retrieved by use of the magnetic extractor through a fiberoptic bronchoscope under fluoroscopic guidance.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Family Planning and Reproductive Health Care
سال: 2008
ISSN: 1471-1893
DOI: 10.1783/147118908786000622