Normative Values for Isometric Muscle Force Measurements Obtained With Hand-held Dynamometers

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normative values for isometric muscle force measurements obtained with hand-held dynamometers.

BACKGROUND AND PURPOSE The extent of a patient's impairment can be established by comparing measurements of that patient's performance with normative values obtained from apparently unimpaired individuals. Only a few studies have described normative values for muscle strength measured by hand-held dynamometry. The purpose of this study of older adults, therefore, was to obtain normative values ...

متن کامل

Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults

[Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric k...

متن کامل

Hand-Held Dynamometry Isometric Torque Reference Values for Children and Adolescents

PURPOSE To establish hand-held dynamometry (HHD) maximal isometric muscle torque (MIT) reference values for children and adolescents who are developing typically. METHODS The MIT of 10 upper and lower limb muscle groups was assessed in 351 Caucasian youth (4 years 2 months to 17 years) using a standardized HHD protocol, previously shown to be feasible, valid, and reliable. RESULTS The mean ...

متن کامل

Hand-held myometry: reference values.

In thirteen major muscle groups of 50 healthy females and 50 males, aged 20-60 years, maximum voluntary contraction was measured with a hand-held dynamometer. The intrasession variation, the left-right variation, and the fifth and fiftieth centile values were calculated. The ratio of two observations within one session ranged from 0.85 to 1.18 and the ratio of left to right ranged from 0.82 to ...

متن کامل

Reference values for isometric muscle force among workers for the Netherlands: a comparison of reference values

BACKGROUND Muscle force is important for daily life and sports and can be measured with a handheld dynamometer. Reference values are employed to quantify a subject's muscle force. It is not unambiguous whether reference values can be generalized to other populations. Objectives in this study were; first to confirm the reliability of the utilization of hand-held dynamometers for isometric streng...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Therapy

سال: 1996

ISSN: 0031-9023,1538-6724