Normal Sonographic Optic Nerve Sheath Diameter among Children in South Western Nigeria

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transorbital Sonographic Evaluation of Normal Optic Nerve Sheath Diameter in Healthy Volunteers in Bangladesh

INTRODUCTION Measurement of optic nerve sheath diameter (ONSD) by ultrasound is increasingly used as a marker to detect raised intracranial pressure (ICP). ONSD varies with age and there is no clear consensus between studies for an upper limit of normal. Knowledge of normal ONSD in a healthy population is essential to interpret this measurement. METHODS In a prospective observational study, O...

متن کامل

Optic nerve sheath diameter in normal-tension glaucoma patients.

BACKGROUND To report on the optic nerve sheath diameter (ONSD) in patients with normal-tension glaucoma (NTG) compared with controls without known optic nerve (ON) or intracranial disease. METHODS In 18 patients with NTG (mean age 64.9 ± 8.9 years; 7 women and 11 men), CT of the orbit was performed. 17 age- and gender-matched patients without ON or intracranial disease, who underwent CT of th...

متن کامل

Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults

BACKGROUND Measurement of optic nerve sheath diameter (ONSD) is a fast and non-invasive method in detecting elevated intracranial pressure. However, the reported normal range of ONSD was inconsistent. The objective of the study was to determine the normal range of ONSD in healthy Chinese adults. METHODS Eyeball transverse diameter (ETD), optic nerve diameter (OND), and ONSD were measured by u...

متن کامل

sonographic optic nerve sheath diameter as a screening tool for detection of elevated intracranial pressure

introduction: timely diagnosis and treatment of post traumatic, elevated intracranial pressure (eicp), could reduce morbidity and mortality, as well as improve patients’ outcome. this study is trying to evaluate the diagnostic accuracy of sonographic optic nerve sheath diameter (onsd) in detection of eicp. methods: sonographic onsd of patients with head trauma or cerebrovascular accident suspic...

متن کامل

Bedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children.

STUDY OBJECTIVE We investigate the test performance of emergency physician-performed sonographic measurement of optic nerve sheath diameter for diagnosis of increased intracranial pressure. METHODS Children between the ages of 0 and 18 years with suspected increased intracranial pressure were prospectively recruited from the emergency department and ICU of an urban, tertiary-level, freestandi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH

سال: 2019

ISSN: 2249-782X

DOI: 10.7860/jcdr/2019/38451.12518