Validity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content
Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...
متن کاملOxygen saturation and outcomes in preterm infants.
BACKGROUND The clinically appropriate range for oxygen saturation in preterm infants is unknown. Previous studies have shown that infants had reduced rates of retinopathy of prematurity when lower targets of oxygen saturation were used. METHODS In three international randomized, controlled trials, we evaluated the effects of targeting an oxygen saturation of 85 to 89%, as compared with a rang...
متن کاملDiscrepancies between arterial oxygen saturation and functional oxygen saturation measured with pulse oximetry in very preterm infants.
BACKGROUND Discrepancies between pulse oximetry saturation (SpO(2)) and arterial saturation (SaO(2)) at low blood oxygenation values have been previously reported with significant variations among instruments and studies. Whether pulse oximeters that attenuate motion artifact are less prone to such discrepancies is not well known. OBJECTIVE To prospectively assess the agreement of the Masimo ...
متن کاملAppropriate levels of oxygen saturation for preterm infants.
Although oxygen is probably the most common therapy delivered to small or sick newborns in the past 75 years, what constitutes appropriate oxygenation for these infants remains highly controversial. The lack of direct evidence, in the form of randomised trials, of the effects of different oxygen levels on meaningful, long-term outcomes has fuelled this controversy and contributed to the signifi...
متن کاملArterial oxygen saturation profiles in healthy preterm infants.
AIM To construct a reference range of SpO2 values in healthy preterm infants using a simple data logging device. METHODS Thirty three healthy preterm infants were monitored for a continuous period of 4 hours at rest using an Ohmeda Biox 3700 E Pulse Oximeter and an electronic data logger (Rustrack Ranger). Stored data were downloaded and saved as individual files on a personal computer. RES...