Normal liver-to-heart transit time and shunt fraction after transplenic injection of 99MTC-pertechnetate in healthy cats

نویسندگان

چکیده

Portosystemic shunts (PSS) are rare vascular anomalies in cats. Transsplenic portal scintigraphy (TSPS) can aid diagnosing PSS Although the actual performance of scan remains same between species, it is questionable whether generally accepted transit time seven seconds for small dogs be applied to cats, thereby influencing shunt fraction (SF) calculation. In this study, normal mean and SF were determined a population cats without following two methods established canine medicine. For both, ± SD was calculated as 6.75 1.58 7.40 1.64 respectively, significant difference both methods. The results confirmed validity used calculation average (± SD) study 0.73 % (±0.74; range 0.11-2.48%).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of 99mTc-DTPA transit times in normal kidney [Persian]

Introduction: Renal dynamic study is a well-established and popular test in routine practice of nuclear medicine. The test is non-invasive, rapid and unique in evaluation of the kidney function. In despite of its clinical values, the parameters derived from renogram are physiologically meaningless. That is due to the fact that renogram is not the true kidney function. From mathematical po...

متن کامل

Clinical need for both scintigraphy with technetium-99m GSA and per-rectal portal scintigraphy in some patients with chronic liver disease.

Scintigraphy with 99mTc-diethylenetriaminepentaacetate with galactosyl human serum albumin (99mTc-GSA) and per-rectal portal scintigraphy are useful for evaluating hepatic functional reserve and portal circulation, respectively. We did the procedures simultaneously in some patients to examine the relationship between hepatic functional reserve and portal circulation in chronic liver disease. Sc...

متن کامل

Effect of Epidural Anesthesia with Lidocaine and Bupivacaine on Gastrointestinal Transit Time in Healthy Dogs

Objective- To evaluate the effect of epidural anesthesia with lidocaine and bupivacaine on transit time of barium sulfate contrast medium through gastrointestinal (GI) tracts in healthy dogs. Design- Prospective, randomized experimental study. Animals-Five healthy mixed breed male dogs with 19.2±7.8 months age and 19.9±3.3 kg weight Procedure- The animals received one of the treatments of sa...

متن کامل

calculation of 99mtc-dtpa transit times in normal kidney [persian]

introduction: renal dynamic study is a well-established and popular test in routine practice of nuclear medicine. the test is non-invasive, rapid and unique in evaluation of the kidney function. in despite of its clinical values, the parameters derived from renogram are physiologically meaningless. that is due to the fact that renogram is not the true kidney function. from mathematical points o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Vlaams Diergeneeskundig Tijdschrift

سال: 2021

ISSN: ['0303-9021']

DOI: https://doi.org/10.21825/vdt.v90i6.21085