Nonlinear optimal oil damper design in seismically controlled multi-story building frame
نویسندگان
چکیده
منابع مشابه
Semiactive Neuro-control for Seismically Excited Structure Using Mr Damper
A new semiactive control strategy for seismic response reduction using a neurocontroller and a magnetorheological (MR) fluid damper is proposed. The proposed control system adopts a clipped algorithm which induces the MR damper to generate approximately the desired control force. The improved neuro-controller, which was developed by employing the training algorithm based on a cost function and ...
متن کاملOptimal Design of an Impact Damper for a Nonlinear Friction-Driven Oscillator
In the present study a Friction-Driven oscillator is investigated analytically using perturbation method and numerically with Runge–Kutta’s integration procedure. The analytical method is also used to investigate damping performance of a single-particleimpact damper on amplitude and frequency of system over a wide range of particle-to-structure mass ratios, clearance, and coefficients of restit...
متن کاملSeismic Response Reduction of a Building Using Top-Story Isolation System with MR Damper
In this study, the adaptability of a semi-active top-story isolation system with an MR damper for reduction of seismic responses of tall buildings has been investigated. To this end, a 20-story building structure was selected as an example. Low damping elastomeric bearings and an MR damper were used to compose a smart top-story isolation system. Artificial earthquakes generated based on design ...
متن کاملDesign of Nonlinear Optimal Control Systems Using Jordan Controlled Form
The problem of control systems design for nonlinear plants still has no exhaustive solution. This problem is commonly solved on the basis of transformation of the nonlinear plant equations to some simple. Such approach simplifies the solution of the control system design problem and makes the solution analytical. For design of the optimal control systems for the nonlinear plants, their equation...
متن کاملMulti-objective Optimization of Semi-active Control of Seismically Exited Buildings Using Variable Damper and Genetic Algorithms
Semi-active fluid viscous dampers as a subset of control systems have shown their ability to reduce seismic responses of tall buildings. In this paper, multi-objective optimization of the performance of this group of dampers in reducing the seismic responses of buildings is studied using multi-objective genetic algorithms. For numerical example, two 7 and 18 stories buildings are chosen and mod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Soil Dynamics and Earthquake Engineering
سال: 2013
ISSN: 0267-7261
DOI: 10.1016/j.soildyn.2012.08.010