Nonlinear Control of an Active Magnetic Bearing with Output Constraint
نویسندگان
چکیده
منابع مشابه
Adaptive control of an active magnetic bearing with external disturbance.
Adaptive back stepping control (ABC) is originally applied to a linearized model of an active magnetic bearing (AMB) system. Our control goal is to regulate the deviation of the magnetic bearing from its equilibrium position in the presence of an external disturbance and system uncertainties. Two types of ABC methods are developed on the AMB system. One is based on full state feedback, for whic...
متن کاملModelling of Control System for an Active Magnetic Bearing
Active Magnetic Bearing (AMB) supports a rotor by magnetic attractive forces, without any mechanical contact. The paper presents a field-circuit model of an active magnetic bearing including its control loop. The basic parameters of the active magnetic system has been obtained from a FEM analysis of an magnetic bearing actuator. The position control system is based on operation of the local con...
متن کاملAnalysis of Vibration Characteristics of PD Control Active Magnetic Bearing and Cracked Rotor System (RESEARCH NOTE)
Crack fault of rotor is one of the most prominent problems faced by magnetic bearing rotor system. In order to improve the safety performance of this kind of machinery, it is necessary to research the vibration characteristics of magnetic bearing cracked rotor system. In this paper, the stiffness model of the crack shaft element was established by the strain energy release rate (SERR) theory. T...
متن کاملOptimized Fuzzy Logic for Nonlinear Vibration Control of Aircraft Semi-active Shock Absorber with Input Constraint (TECHNICAL NOTE)
Landing impact and runway unevenness have proximate consequence on performance of landing gear system and conduce to discomfort of passengers and reduction of the pilot’s capability to control aircraft. Finally, vibrations caused by them result in structure fatigue. Fuzzy logic controller is used frequently in different applications because of simplicity in design and implementation. In the pre...
متن کاملActive Magnetic Bearing Control with Zero Steady-State Power Loss
In this paper, we address the problem of controlling an active magnetic bearing with reduced ohmic power losses. A solution is proposed which introduces an exponentially decaying bias ßux in the nonlinear control law. To avoid control singularities, the closed-loop system is exponentially stabilized at a faster rate than the bias decay. In the steady state, the proposed controller has zero bias...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Electrical and Computer Engineering (IJECE)
سال: 2018
ISSN: 2088-8708,2088-8708
DOI: 10.11591/ijece.v8i5.pp3666-3677