Noninvasive Measurement of Time-Varying Arterial Wall Elastance Using a Single-Frequency Vibration Approach

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A vibration-based approach to quantifying the dynamic elastance of the superficial arterial wall

BACKGROUND The purpose of this study is to propose a novel method for assessing dynamic elastance of the superficial arterial wall using the sinusoidal minute vibration method. METHODS A sinusoidal signal was used to drive a vibrator which induced a displacement of 0.15 mm with a frequency range between 40 and 85 Hz. The vibrator closely contacted with the wall of a superficial radial artery,...

متن کامل

Single-beat estimation of end-systolic elastance using bilinearly approximated time-varying elastance curve.

BACKGROUND Although left ventricular end-systolic elastance (E(es)) has often been used as an index of contractility, technical difficulties in measuring volume and in changing loading conditions have made its clinical application somewhat limited. By approximating the time-varying elastance curve by 2 linear functions (isovolumic contraction phase and ejection phase) and estimating the slope r...

متن کامل

Time-Varying Elastance Model

Background Contractile function of the ex vivo, isolated left atrium (LA) has been described by a time-varying elastance, but this atrial chamber property has not been shown in vivo. Methods and Results Instantaneous LA pressure-volume (P-V) relations were studied in 12 anesthetized, autonomically blocked, atrially paced dogs. LA volume was calculated from orthogonal sonomicrometer pairs using ...

متن کامل

A new method to measure regional myocardial time-varying elastance using minute vibration.

We developed a new technique to evaluate regional myocardial elastance using minute vibration. In 13 isolated cross-circulated canine hearts, we applied small sinusoidal vibrations of displacement to the left ventricular surface at various frequencies (50-100 Hz). Using the measured displacement and force between the vibrator head and myocardium, we derived myocardial elastance on the basis of ...

متن کامل

A Real-Time Vibration Frequency Measurement System of Bridge Pier

This study developed a real-time remote monitoring system (RTRMS) to receive the vibration frequency of bridge pier. The system included a front station and a middle station. A multi-hop wireless routing is employed to transmit the data from the front to the middle station. The front station includes a receiver equipped to receive the vibration frequency, and a wireless sensor network to transm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2020

ISSN: 1424-8220

DOI: 10.3390/s20226463