Noninvasive measurement of blood volume in hemodialysis patients.
نویسندگان
چکیده
منابع مشابه
Hemodialysis Volume-Associated Ambulatory Blood Pressure Patterns in Hemodialysis Patients
Although volume excess causes hypertension, whether it also affects circadian patterns of arterial pressures among hemodialysis patients remains unknown. To test the notion of whether volume overload is associated with a unique blood pressure (BP) “signature,” a posthoc analysis was performed among 145 patients participating in the Dry-Weight Reduction in Hypertensive Hemodialysis Patients rand...
متن کاملOptimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کاملDiagnostic utility of blood volume monitoring in hemodialysis patients.
BACKGROUND Assessment of volume state is difficult in hemodialysis patients. Whether continuous blood volume monitoring can improve the assessment of volume state is unclear. STUDY DESIGN Diagnostic test study. SETTINGS & PARTICIPANTS Asymptomatic long-term hemodialysis patients (n = 150) in 4 university-affiliated hemodialysis units. INDEX TESTS Ultrafiltration rate (UFR) divided by post...
متن کاملEffects of relative blood volume-controlled hemodialysis on blood pressure and volume status in hypertensive patients.
In hypertensive hemodialysis (HD) patients, dry weight reduction to normalize blood pressure (BP) often results in increased frequency of HD hypotension. Because HD with blood volume tracking (BVT) has been shown to improve intra-HD hemodynamic stability, we performed a prospective, randomized study to test whether BVT is more effective than standard hemodialysis (SHD) in the management of hype...
متن کاملVolume-associated ambulatory blood pressure patterns in hemodialysis patients.
Although volume excess causes hypertension, whether it also affects circadian patterns of arterial pressures among hemodialysis patients remains unknown. To test the notion of whether volume overload is associated with a unique blood pressure (BP) "signature," a posthoc analysis was performed among 145 patients participating in the Dry-Weight Reduction in Hypertensive Hemodialysis Patients rand...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American Society of Nephrology
سال: 1996
ISSN: 1046-6673,1533-3450
DOI: 10.1681/asn.v781241